Download
Specifications of Hard Polyurethane Tubing (Standard Type)
Maximum operating pressure
Series List
Nominal | TUH0428 | TUH0644 | TUH0858 | TUH1073 | TUH1288 |
---|---|---|---|---|---|
Outer diameter (mm) | 4 | 6 | 8 | 10 | 12 |
Inner diameter (mm) | 2.8 | 4.4 | 5.8 | 7.3 | 8.8 |
Specifications
Fluid | Air | |||||
---|---|---|---|---|---|---|
Maximum operating pressure MPa |
20°C | 0.8 | ||||
40°C | 0.65 | |||||
60°C | 0.5 | |||||
Applicable fittings | One-touch fittings | |||||
Minimum bending radius mm | 10 | 18 | 24 | 30 | 36 | |
Operating temperature | -20 to 60°C | |||||
Material | Polyurethane |
Specifications of Hard Polyurethane Tubing (High-Pressure Type)
Maximum operating pressure
Series List
Nominal | TUH0425 | TUH0604 | TUH0805 | TUH1065 | TUH1208 |
---|---|---|---|---|---|
Outer diameter (mm) | 4 | 6 | 8 | 10 | 12 |
Inner diameter (mm) | 2.5 | 4 | 5 | 6.5 | 8 |
Specifications
Fluid | Air | |||||
---|---|---|---|---|---|---|
Maximum operating pressure MPa |
20°C | 1.0 | ||||
40°C | 0.85 | |||||
60°C | 0.7 | |||||
Applicable fittings | One-touch fittings, insert fittings, miniature fittings | |||||
Minimum bending radius mm | 10 | 15 | 20 | 27 | 35 | |
Operating temperature | -20 to 60°C | |||||
Material | Polyurethane |
Common Items
Minimum bending radius
Bend the tube into a U shape at a temperature of 20°C. Fix one end and close the loop gradually. Measure 2R when the tube breaks or is crushed.
Caution
- 1. Please consult with SMC regarding other fluids. Because ester polyurethane is used, water cannot be used due to the occurrence of hydrolysis.
- 2. Abnormal temperature rise caused by adiabatic compression may result in the tube bursting.
- 3. The value of the minimum bending radius is measured at a temperature of 20°C as shown above.