Download
Specifications Of Fluoropolymer Tubing TL/TIL Series
Appearance of Fluoropolymer Tubing TL/TIL Series
Burst Pressure Drop Curve
Series List And Specifications
– | Metric Sizes (TL series) | Inch Sizes (TIL series) | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Tubing model | TL0403 | TL0604 | TL0806 | TL1008 | TL1210 | TL1916 | TIL01 | TIL05 | TIL07 | TIL11 | TIL13 | TIL19 | TIL25 | |
Nominal diameter | – | – | – | – | – | – | 1/8 “ | 3/16 “ | 1/4 “ | 3/8 “ | 1/2 “ | 3/4 “ | 1 “ | |
Tubing Size | ø4 × ø3 | ø6 × ø4 | ø8 × ø6 | ø10 × ø8 | ø12 × ø10 | ø19 × ø16 | 1/8 “× 0.086 “ | 3/16 “× 1/8 “ | 1/4 “×5/32 “ | 3/8 “×1/4 “ | 1/2 “×3/8 “ | 3/4 “×5/8 “ | 1 “×7/8 “ | |
Outer diameter (mm) | Basic diameter | 4 | 6 | 8 | 10 | 12 | 19 | 3.18 | 4.75 | 6.35 | 9.53 | 12.7 | 19.05 | 25.4 |
Tolerance | ±0.1 | +0.2 -0.1 |
±0.1 | +0.2 -0.1 |
||||||||||
Thickness mm | Basic diameter | 0.5 | 1 | 1.5 | 0.5 | 0.8 | 1.2 | 1.6 | ||||||
Tolerance | ±0.05 | ±0.1 | ±0.15 | ±0.05 | ±0.08 | ±0.12 | ±0.15 | |||||||
Roll | 10 m | – | – | – | ● | ● | ● | – | – | – | ● | ● | – | – |
20 m | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
50 m | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
100 m | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | – | |
16 m (50 ft) | – | – | – | – | – | – | ● | ● | ● | ● | ● | ● | ● | |
33 m (100 ft) | – | – | – | – | – | – | ● | ● | ● | ● | ● | ● | ● | |
Straight pipe | 2 m | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
Color | Translucent (material color) | |||||||||||||
Applicable Fluids | See catalog | |||||||||||||
Applicable fittings | Fluoropolymer fittings LQ Series | |||||||||||||
Maximum operating pressure MPa |
20°C | 1.0 | 1.0 | 1.0 | 0.9 | 0.7 | 0.6 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 0.7 | 0.5 |
100°C | 0.45 | 0.64 | 0.43 | 0.33 | 0.27 | 0.24 | 0.59 | 0.62 | 0.73 | 0.62 | 0.43 | 0.26 | 0.19 | |
200°C | 0.21 | 0.29 | 0.20 | 0.15 | 0.12 | 0.11 | 0.27 | 0.28 | 0.34 | 0.28 | 0.20 | 0.12 | 0.09 | |
260°C | 0.09 | 0.12 | 0.08 | 0.06 | 0.05 | 0.05 | 0.11 | 0.12 | 0.14 | 0.12 | 0.08 | 0.05 | 0.04 | |
Burst pressure MPa (at 20°C) | 4.9 | 6.9 | 4.7 | 3.6 | 2.9 | 2.6 | 6.4 | 6.7 | 7.9 | 6.7 | 4.6 | 2.8 | 2.0 | |
Minimum bending radius mm |
Recommended radius | 35 | 35 | 60 | 100 | 130 | 220 | 20 | 25 | 35 | 60 | 95 | 220 | 400 |
Tube close bend radius | 20 | 20 | 40 | 65 | 110 | 160 | 12 | 20 | 20 | 30 | 60 | 160 | 290 | |
Maximum operating temperature (fixed usage) | 260°C | |||||||||||||
Material | Super PFA |
Note 1) When using the product at a temperature other than those shown in the table above, use it at the maximum operating pressure or less that is calculated from the following formula.
(Maximum operating pressure) = 1/4 × (Burst pressure drop coefficient) × (Burst pressure at 20°C)
Note 2) When using a fluid in liquid form, the surge pressure must be no more than the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to the fittings and tubing. Furthermore, abnormal temperature rise caused by adiabatic compression may result in the tubing bursting.
Note 3) Do not use this product in a manner in which the tubing is not fixed. Observe the lesser value of the maximum operating pressure between the tubing and fittings. A material change over a long duration or due to high temperature may cause leakage. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected. (Refer to the notes on maintenance in the catalog.) For other precautions, refer to “Fittings & Tubing Precautions” in the catalog. When using the fluoropolymer fittings, refer to the precautions in the catalog.
Note 4) The minimum bending radius is the value measured as shown in the figure on the left.
- Use a tube above the recommended minimum bending radius.
- The tubing may be bent if used under the recommended minimum bending radius. Therefore, refer to the tube close bend radius and make sure that the tubing is not bent or flattened.
- The tube close bend radius is not guaranteed. The value of 2R is the value measured with a flattened tube using the method shown in the figure on the left.
- The minimum bending radius shown above does not apply to straight pipes (2 m).
Note 5) As for other commercial items, there are some cases in which the item cannot be connected due to the tolerance of dimensions.