Download
Flame Resistant (Equivalent to UL-94 Standard V-0) FR Three-Layer Polyurethane Tubing, TRTU Series Details
Flame Resistant (Equivalent to UL-94 Standard V-0) FR Three-Layer Polyurethane Tubing, TRTU Series product images
Three-layer structure
Flame Resistant (Equivalent to UL-94 Standard V-0) FR Three-Layer Polyurethane Tubing, TRTU Series Specifications
Series Table
Nominal | TRTU0604 | TRTU0805 | TRTU1065 | TRTU1208 | |
---|---|---|---|---|---|
Inner Tubing Outer Diameter (mm) | 6 | 8 | 10 | 12 | |
Inner Tubing Inner Diameter (mm) | 4 | 5 | 6.5 | 8 | |
Outer Layer Thickness (mm) | 1 | 1 | 1 | 1 | |
Outer Layer Color | Black (B) | ● | ● | ● | ● |
White (W) | ● | ● | ● | ● | |
Red (R) | ● | ● | ● | ● | |
Blue (BU) | ● | ● | ● | ● | |
Yellow (Y) | ● | ● | ● | ● | |
Green (G) | ● | ● | ● | ● |
- ●: 20-m roll
- *All inner tubes are black in color.
Specifications
Working Fluids Note 1 | Air, water | ||||
---|---|---|---|---|---|
Applicable Fittings | FR Single-Action Fittings, KR-W2 Series Metal Single-Action Fittings, KQB2 Series |
||||
Maximum Operating Pressure (MPa) | 20°C | 0.8 | |||
40°C | 0.65 | ||||
60°C | 0.5 | ||||
Minimum Bending Radius (mm) Note 2 | 50 | 60 | 70 | 80 | |
Ambient and Working Fluid Temperature | -20 to +60°C, Water: 0 to 40°C (no freezing) | ||||
Materials | Inner Tube | Polyurethane | |||
Middle Layer | Aluminum-laminated film | ||||
Outer Layer | Polyolefin resin (equivalent to UL-94 standard V-0) |
Note 1: Can be used for general industrial water. The surge pressure must not exceed the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will damage the fittings and tubes.
Note 2: The minimum bending radius is the representative value measured as shown in the figure on the left. The tubing may be bent if used under the recommended minimum bending radius. Please allow additional margin for flexibility.
- *Abnormal temperature rises caused by adiabatic compression can result in the tube bursting.