Fluid and Ambient Temperature
- Fluid temperature: -10* to +60°C
- Ambient temperature: -20 to +60°C
*Dew point temperature: -10°C or less
Valve Leakage Amount (Air*1, *2) Internal Leakage / Seal Material: NBR (FKM)*3
- Aluminum body type: 15 cm3/min or less
- Resin body type: 15 cm3/min or less
- Metal body type: 1 cm3/min or less
Valve Leakage Amount (Air*1) External Leakage / Seal Material: NBR (FKM)*3
- Aluminum body type: 15 cm3/min or less
- Resin body type: 15 cm3/min or less
- Metal body type: 1 cm3/min or less
*1: The leakage rate is at an ambient temperature of 20°C.
*2: The leakage rate is at a pressure differential of 0.01 MPa up to the maximum operating pressure differential.
*3: See the SMC catalog regarding FKM sealing material and then select based on the other options.
*4: If using for low vacuum specifications (up to 133 Pa.abs) pay attention to the leakage amount detailed above.
For Air (N.O. Type)
For air (N.O. type) external appearance
Fluid and Ambient Temperature
- Fluid temperature: -10* to +60°C
- Ambient temperature: -20 to +60°C
*Dew point temperature: -10°C or less
Valve Leakage Amount (Air*1, *2) Internal Leakage / Seal Material: NBR (FKM)*3
- Aluminum body type: 15 cm3/min or less
- Resin body type: 15 cm3/min or less
- Metal body type: 1 cm3/min or less
Valve Leakage Amount (Air*1) External Leakage / Seal Material: NBR (FKM)*3
- Aluminum body type: 15 cm3/min or less
- Resin body type: 15 cm3/min or less
- Metal body type: 1 cm3/min or less
*1: The leakage rate is at an ambient temperature of 20°C.
*2: The leakage rate is at a pressure differential of 0.01 MPa up to the maximum operating pressure differential.
*3: See the SMC catalog regarding FKM sealing material and then select based on the other options.
For Water (N.C. Type)
*Can also be used for air (vacuums up to 133 Pa.abs). However, be aware that the maximum operating pressure differential and flow rate characteristics will be limited to the specifications range for the air-use type.
For water (N.C. type) external appearance
Fluid and Ambient Temperature
- Fluid temperature: 1 to 60°C
- Ambient temperature: -20 to +60°C
*No freezing
Valve Leakage Amount (Water*1, *2) Internal Leakage / Seal Material: NBR (FKM)*3
- 0.1 cm3/min or less
Valve Leakage Amount (Water*1) External Leakage / Seal Material: NBR (FKM)*3
- 0.1 cm3/min or less
*1: The leakage rate is at an ambient temperature of 20°C.
*2: The leakage rate is at a pressure differential of 0.01 MPa up to the maximum operating pressure differential.
*3: See the SMC catalog regarding FKM sealing material and then select based on the other options.
For Water (N.O. Type)
For water (N.O. type) external appearance
Fluid and Ambient Temperature
- Fluid temperature: 1 to 60°C
- Ambient temperature: -20 to +60°C
*No freezing
Valve Leakage Amount (Water*1, *2) Internal Leakage / Seal Material: NBR (FKM)*3
- 0.1 cm3/min or less
Valve Leakage Amount (Water*1) External Leakage / Seal Material: NBR (FKM)*3
- 0.1 cm3/min or less
*1: The leakage rate is at an ambient temperature of 20°C.
*2: The leakage rate is at a pressure differential of 0.01 MPa up to the maximum operating pressure differential.
*3: See the SMC catalog regarding FKM sealing material and then select based on the other options.
For Oil (N.C. Type)
- *Can also be used for air or water. However, be aware that the maximum operating pressure differential and flow rate characteristics will be limited to the specifications range for the respective types of fluid being used.
- *When the fluid is oil ensure the kinematic viscosity is 50 mm2/s or less. The special construction of the armature adopted in the built-in full wave rectifier type gives an improvement in the OFF response by providing clearance on the adsorbed surface when it is switched ON.
For oil (N.C. type) external appearance
Fluid and Ambient Temperature
- Fluid temperature: -5* to +60°C
- Ambient temperature: -20 to +60°C
*Kinematic viscosity: 50 mm2/s or less
Valve Leakage Amount (Oil*1, *2) Internal Leakage / Seal Material: FKM
- 0.1 cm3/min or less
Valve Leakage Amount (Oil*1) External Leakage / Seal Material: FKM
- 0.1 cm3/min or less
*1: The leakage rate is at an ambient temperature of 20°C.
*2: The leakage rate is at a pressure differential of 0.01 MPa up to the maximum operating pressure differential.
For Oil (N.O. Type)
For oil (N.O. type) external appearance
Fluid and Ambient Temperature
- Fluid temperature: -5* to +60°C
- Ambient temperature: -20 to +60°C
*Kinematic viscosity: 50 mm2/s or less
Valve Leakage Amount (Oil*1, *2) Internal Leakage / Seal Material: FKM
- 0.1 cm3/min or less
Valve Leakage Amount (Oil*1) External Leakage / Seal Material: FKM
- 0.1 cm3/min or less
*1: The leakage rate is at an ambient temperature of 20°C.
*2: The leakage rate is at a pressure differential of 0.01 MPa up to the maximum operating pressure differential.
*Lists information for only some products.
VXZ Series Common Items
Standard Specification
Valve Specifications | Valve Structure | Zero differential pressure type pilot-operated 2 port diaphragm type | |
---|---|---|---|
Withstand Pressure | 2.0 MPa (resin body type: 1.5 MPa) | ||
Body Material | Aluminum, resin, C37, SUS *1 | ||
Seal Materials | NBR, FKM, EPDM | ||
Enclosure | Dustproof, jetproof (IP65)*2, *4 | ||
Environment | Locations without corrosive or explosive gases | ||
Coil Specifications | Rated Voltage | AC | 100 V AC, 200 V AC, 110 V AC, 230 V AC, (220 V AC, 240 V AC, 48 V AC, 24 V AC)*3 |
DC | 24 V DC, (12 V DC)*1 | ||
Allowable Voltage Fluctuation | ±10% of rated voltage | ||
Allowable Leakage Voltage | AC (Built-In Full Wave Rectifier Type) | 5% or less of rated voltage | |
DC | 2% or less of rated voltage | ||
Coil Insulation Type | Class B (for air/water/oil), class H (for high temperature water / high temperature oil) |
*1: Body material: aluminum. Only VXZ23/VXZ2A use resin.
*2: Electrical entry “Faston” type terminal is IP40 compliant.
*3: Voltage inside () indicates special voltage. (See the SMC catalog)
*4: See the SMC catalog for information on protection grades. Contact the SMC support center regarding use in locations that require water resistance.
VXZ2A0AAXB
VXZ2A0AAZ
VXZ2A0AB
VXZ2A0ABZXB
VXZ2A0AD
VXZ2A0ADX332
VXZ2A0AE
VXZ2A0AF
VXZ2A0AFZ
VXZ230AABX332
VXZ230AAX332F
VXZ230ABCXB
VXZ230ABDXB
VXZ230ACBXB
VXZ230AEZ
VXZ230AFG
VXZ230AFGXB
VXZ240FAHXB
VXZ240FAX332
VXZ240FCX332
VXZ240FFC
VXZ240FGAXCA
VXZ240FGBXBB
VXZ240FGDXBA
VXZ250HAC
VXZ250HAZXBC
VXZ250HBE
VXZ250HBXCC
VXZ250HFE
VXZ250HFXBB
VXZ250HGBXCB
VXZ250HGG
VXZ260KEB
VXZ260KGAXBA
VXZ260KGF
VXZ260KGH
VXZ260KHXBA
VXZ260KHXBB
VXZ260KKXBB
VXZ260KKXBC
VXZ2A0AAB
VXZ2A0AEBXB
VXZ2A0AKXB
VXZ2A0AZ2AAXB
VXZ2A0AZ2AXCA
VXZ2A0AZ2AXCC
VXZ2A0AZ2BXBB
VXZ2A0AZ2E
VXZ2A0BAAX332B
VXZ2B0FFXBB
VXZ2B0FGC
VXZ2B0FGZ
VXZ2B0FHXB
VXZ2B0FZ2CXB
VXZ2B0FZ2KZXB
VXZ2B0FZ2V
VXZ2B0FZ2VB
VXZ2C0HBXBA
VXZ2C0HGE
VXZ2C0HJFXB
VXZ2C0HMB
VXZ2C0HZ1BC
VXZ2C0HZ1DB
VXZ2C0HZ1FB
VXZ2C0HZ1GA
VXZ2D0KFD
VXZ2D0KFXB
VXZ2D0KGFXB
VXZ2D0KGXB
VXZ2D0KJA
VXZ2D0KLB
VXZ2D0KQXB
VXZ2D0KT
VXZ2D0KV