Download
Speed Controller With One-Touch Fittings, In-Line Type, Panel Mount Type Specifications – Van tiết lưu SMC
Speed Controller With One-Touch Fittings external appearance
Speed Controller With One-Touch Fittings component names
Model
Model | Applicable tubing outer diameter | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Metric size | Inch Size | ||||||||||||
3.2 | 4 | 6 | 8 | 10 | 12 | 1/8″ | 5/32″ | 3/16″ | 1/4″ | 5/16″ | 3/8″ | 1/2″ | |
AS1001F | ● | ● | ● | – | – | – | ● | ● | ● | ● | – | – | – |
AS2001F | – | ● | ● | – | – | – | – | ● | ● | ● | – | – | – |
AS2051F | – | – | ● | ● | – | – | – | – | ● | ● | ● | – | – |
AS3001F | – | – | ● | ● | ● | ● | – | – | – | ● | ● | ● | – |
AS4001F | – | – | – | – | ● | ● | – | – | – | – | – | ● | ● |
Specifications
Usable fluids | Air |
---|---|
Proof pressure | 1.5 MPa |
Max. operating pressure | 1 MPa |
Min. operating pressure | 0.1 MPa |
Ambient and fluid temperature | -5 to 60°C (no freezing) |
Applicable tubing materialNote 1) | Nylon, soft nylon, polyurethane |
Note 1) Use caution at the max. operating pressure when using soft nylon or polyurethane tubing. (Refer to the catalog for details.)
Note 2) All brass components are electroless nickel plated.
Flow rate and sonic conductance
Model | AS1001F | AS2001F | AS2051F | AS3001F | AS4001F | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Tube outer diameter | Metric size | ø3.2, ø4, ø6 | ø4 | ø6 | ø6 | ø8 | ø6 | ø8 | ø10, ø12 | ø10 | ø12 |
Inch Size | ø1/8 “, ø5/32 “ø3/16 “, ø1/4 “ | ø5/32 “ | ø3/16 “, ø1/4 “ | ø3/16 “ | ø1/4 “, ø5/16 “ | ø1/4 “ | ø5/16 “ | ø3/8 “ | ø3/8 “ | ø1/2 “ | |
Controlled flow Free flow |
Flow rate L/min (ANR) |
100 | 130 | 230 | 290 | 460 | 420 | 660 | 920 | 1,050 | 1,390 |
Sonic conductance dm3/(s·bar) |
0.28 | 0.36 | 0.64 | 0.8 | 1.3 | 1.2 | 1.8 | 2.6 | 2.9 | 3.9 | |
Critical pressure ratio | Controlled flow | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | |||||
Free flow | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 |
Note) Flow rate at a pressure of 0.5 MPa and a temperature of 20℃.
Structural Drawing
AS1001F-04-3-X21
AS1001F-04-3-X21-J
AS1001F-04-3-X214
AS1001F-04-3-X214-J
AS1001F-06-3-X21
AS1001F-06-3-X21-J
AS1001F-06-3-X214
AS1001F-06-3-X214-J
AS1001F-07-3-X21
AS1001F-07-3-X214
AS1001F-23-3-X21-J
AS2001F-03-3-X21
AS2001F-04-3-X21
AS2001F-04-3-X21-J
AS2001F-04-3-X214
AS2001F-04-3-X214-J
AS2001F-06-3-X12
AS2001F-06-3-X21
AS2001F-06-3-X21-J
AS2001F-06-3-X214
AS2001F-06-3-X214-J
AS2001F-07-3-X21
AS2001F-07-3-X21-J
AS2051F-06-3-X214
AS2051F-06-3-X214-J
AS2051F-07-3-X12
AS2051F-07-3-X21
AS2051F-07-3-X214
AS2051F-07-3-X214-J
AS2051F-08-3-X12
AS2051F-08-3-X21
AS2051F-08-3-X21-J
AS2051F-08-3-X214
AS2051F-08-3-X214-J
AS3001F-06-3-X21
AS3001F-06-3-X21-J
AS3001F-06-3-X214
AS3001F-06-3-X214-J
AS3001F-08-3-X21
AS3001F-08-3-X21-J
AS3001F-08-3-X214
AS3001F-10-3-X12
AS3001F-10-3-X21
AS3001F-10-3-X21-J
AS3001F-10-3-X214
AS3001F-10-3-X214-J
AS3001F-11-3-X21
AS3001F-11-3-X214
AS1001F-01-3-J
AS1001F-03-3
AS1001F-03-3-J
AS1001F-04-3
AS1001F-04-3-J
AS1001F-05-3
AS1001F-05-3-J
AS1001F-06-3
AS1001F-06-3-J
AS1001F-07-3
AS1001F-07-3-J
AS1001F-23-3
AS1001F-23-3-J
AS2001F-03-3
AS2001F-03-3-J
AS2001F-04-3
AS2001F-04-3-J
AS2001F-05-3
AS2001F-05-3-J
AS2001F-06-3
AS2001F-06-3-J
AS2001F-07-3
AS2001F-07-3-J
AS2051F-05-3
AS2051F-07-3-J
AS2051F-08-3
AS2051F-08-3-J
AS2051F-09-3
AS2051F-09-3-J
AS3001F-06-3
AS3001F-06-3-J
AS3001F-07-3
AS3001F-07-3-J
AS3001F-08-3
AS3001F-08-3-J
AS3001F-09-3
AS3001F-09-3-J
AS3001F-10-3
AS3001F-10-3-J
AS3001F-11-3
AS3001F-11-3-J
AS3001F-12-3-J
AS4001F-10-3
AS4001F-10-3-J
AS4001F-11-3
AS4001F-11-3-J
AS4001F-12-3
AS4001F-12-3-J
AS4001F-13-3
AS4001F-13-3-J