Refrigerated Air Dryer, Refrigerant R407C (HFC) Standard Temperature Air Inlet, Series IDF□E Specifications – Máy Sấy Khí SMC
IDF22E external appearance
IDF75E external appearance
IDF□E Series JIS symbol
Specifications | Model | ||||||
---|---|---|---|---|---|---|---|
Standard-temperature air inlet | |||||||
IDF22E | IDF37E | IDF55E | IDF75E | ||||
Operating range*3 | Applicable fluid | Compressed Air | |||||
Inlet air temperature (°C) | 5 to 50 | ||||||
Inlet air pressure (MPa) | 0.15 to 1.0 | ||||||
Ambient temperature (humidity) (°C) | 2 to 40 (Relative humidity of 85% or less) | ||||||
*4 | Air flow capacity m3/min |
Standard condition (ANR)*1 |
50 Hz | 3.9 | 5.7 | 8.4 | 11.0 |
60 Hz | 4.3 | 6.1 | 9.8 | 12.4 | |||
Compressor intake condition*2 |
50 Hz | 4.1 | 6.1 | 8.9 | 11.7 | ||
60 Hz | 4.6 | 6.5 | 10.4 | 13.2 | |||
Inlet air pressure (MPa) | 0.7 | ||||||
Inlet air temperature (°C) | 35 | 40 | |||||
Ambient temperature (°C) | 32 | ||||||
Outlet air pressure dew point (°C) | 10 | ||||||
Power supply voltage (frequency)*5 | Single-phase/Three-phase 200 V AC (50 Hz)*5 Single-phase/Three-phase 200/220 V AC (60 Hz) |
Three-phase 200 V AC (50 Hz) Three-phase 200/220 V AC (60 Hz) |
|||||
Electric specifications | Power consumption*6 (W) 50/60 Hz |
Single-phase 200 V | 810/940 | 810/940 | – | – | |
Three-phase 200 V | 850/1,070 | 850/1,070 | 1,450/1,890 | 2,000/2,500 | |||
Operating current*6 (A) 50/60 Hz |
Single-phase 200 V | 4.3/4.7 | 4.3/4.7 | – | – | ||
Three-phase 200 V | 3.3/3.5 | 3.3/3.5 | 6.0/6.6 | 7.2/8.0 | |||
Applicable circuit breaker capacity*7 (A) (Sensitivity current of 30 mA) |
10 (200 V AC) | 15 (200 V AC) | |||||
Condenser | Air-cooled | ||||||
Refrigerant | R407C (HFC) | ||||||
Refrigerant charge (kg) | Single-phase 200 V | 0.42 | 0.73 | – | – | ||
Three-phase 200 V | 0.47 | 0.83 | 0.55 | 0.72 | |||
Auto drain | Float type (normally open) | ||||||
Port size | R1 | R1 1/2 | R2 | ||||
Weight (kg) | 54 | 62 | 100 | 116 | |||
Coating color | Body panel: urban white 1 Base: urban gray 2 |
||||||
Applicable compressor output (Reference) (kW) For screw type |
22 | 37 | 55 | 75 |
*1: Indicates the air flow capacity under the standard condition (ANR) (atmospheric pressure 20°C, relative humidity 65%).
*2: Indicates the air flow capacity converted by the compressor intake condition (atmospheric pressure 32°C, relative humidity 75%).
*3: The operating range does not guarantee use at rated air flow capacity.
*4: If the operating conditions differ from the rating, select the model referring to “Model Selection” in the manufacturer’s catalog.
*5: Refer to “How to Order” in the manufacturer’s catalog when selecting the power supply voltage.
*6: These are reference values under the rated conditions and are not guaranteed. Do not use these as thermal setting values, etc.
*7: Products without option R do not come with a circuit breaker. Purchase a circuit breaker separately.
Structure Principle Diagram (Air/Refrigerant Circuit)
Humid, hot air coming into the air dryer is cooled down by a cooler re-heater (heat exchanger). Water condensed at this time is drained out automatically by the auto drain. Air separated from the water is heated by a cooler re-heater (heat exchanger) to obtain the dried air, which goes through to the outlet side.
Structure principle diagram: IDF22E/IDF37E/IDF55E/IDF75E
IDF22E-20-A
IDF22E-20-ACGR
IDF22E-20-AGMT
IDF22E-20-AR
IDF22E-20-CKR
IDF22E-20-G
IDF22E-20-K
IDF22E-20-M
IDF22E-20-T
IDF22E-30
IDF22E-30-A
IDF22E-30-GT
IDF22E-30-LT
IDF22E-30-T
IDF37E-20
IDF37E-20-AGT
IDF37E-20-K
IDF37E-20-L
IDF37E-20-M
IDF37E-20-MR
IDF37E-20-R
IDF37E-20-T
IDF37E-30
IDF37E-30-A
IDF37E-30-AMT
IDF37E-30-CT
IDF37E-30-G
IDF37E-30-K
IDF37E-30-L
IDF37E-30-LR
IDF37E-30-MR
IDF37E-30-T
IDF55E-30
IDF55E-30-ACRT
IDF55E-30-CL
IDF55E-30-CLT
IDF55E-30-G
IDF55E-30-GL
IDF55E-30-L
IDF55E-30-LT
IDF55E-30-R
IDF55E-30-T