Download
Refrigerant R134a (HFC) Series IDFA□E Specifications – Máy Sấy Khí SMC
JIS symbol
Size
- 3E
- 4E
- 6E
- 8E
- 11E
- 15E1
Standard Specifications
Specifications | Model | ||||||||
---|---|---|---|---|---|---|---|---|---|
Standard-temperature air inlet | |||||||||
IDFA3E | IDFA4E | IDFA6E*9 | IDFA8E | IDFA11E | IDFA15E1 | ||||
Operating range*3 | Applicable fluid | Compressed Air | |||||||
Inlet air temperature (°C) | 5 to 50 | ||||||||
Inlet air pressure (MPa) | 0.15 to 1.0 | ||||||||
Ambient temperature (humidity) (°C) | 2 to 40 (Relative humidity of 85% or less) | ||||||||
*4 | Air flow capacity m3/h | Standard condition (ANR)*1 |
Outlet air pressure dew point 3°C | 12 | 24 | 36 | 65 | 80 | 120 |
Outlet air pressure dew point 7°C | 15 | 31 | 46 | 83 | 101 | 152 | |||
Outlet air pressure dew point 10°C | 17 | 34 | 50 | 91 | 112 | 168 | |||
Compressor intake condition*2 |
Outlet air pressure dew point 3°C | 13 | 25 | 37 | 68 | 83 | 125 | ||
Outlet air pressure dew point 7°C | 16 | 32 | 48 | 86 | 105 | 158 | |||
Outlet air pressure dew point 10°C | 18 | 35 | 52 | 95 | 116 | 175 | |||
Inlet air pressure (MPa) | 0.7 | ||||||||
Inlet air temperature (°C) | 35 | ||||||||
Ambient temperature (°C) | 25 | ||||||||
Power supply voltage | Single-phase 230 V AC (Voltage fluctuation ±10%) 50 Hz | ||||||||
Electric specifications | Power consumption*6 (W) | 180 | 208 | 385 | 420 | ||||
Operating current*6 (A) | 1.2 | 1.4 | 2.7 | 2.9 | |||||
Applicable circuit breaker capacity*5 (Sensitivity current of 30 mA) (A) |
5 | 10 | |||||||
Condenser | Air-cooled | ||||||||
Refrigerant | R134a (HFC) | ||||||||
Refrigerant charge (kg) | 0.15 | 0.2 | 0.23 | 0.27 | 0.29 | 0.47 | |||
Auto drain | Float type (normally open) | ||||||||
Port size | Rc 3/8 | Rc1/2 | Rc3/4 | Rc1 | |||||
Accessories | Hex nipple | ||||||||
Weight (kg) | 18 | 22 | 23 | 27 | 28 | 46 | |||
Coating color | Body panel: urban white 1 Base: urban gray 2 |
||||||||
Compliant standards | EC directive (with EU directive CE marking) |
*1: ANR is the value at 20°C, atmospheric pressure and relative humidity 65%.
*2: Indicates the air flow capacity converted by the compressor intake condition (at 32°C, atmospheric pressure, relative humidity 75%).
*3: The operating range does not guarantee use at rated air flow capacity.
*4: Select the model while referring to “Model Selection” in the manufacturer’s catalog.
*5: Products without option R do not come with a circuit breaker. Purchase an earth leakage breaker separately.
*6: These are characteristic values under rated conditions and are not guaranteed. Do not use these as thermal setting values, etc.
*7: When a short-term interruption of the power supply (including momentary interruption) occurs in this equipment, the restarting of normal operations may require some time or may be impossible due to the operation of protective devices even after the supply of power returns.
IDFA3E-23-A
IDFA3E-23-AC
IDFA3E-23-AG
IDFA3E-23-C
IDFA3E-23-G
IDFA4E-23
IDFA4E-23-A
IDFA4E-23-C
IDFA4E-23-G
IDFA4E-23-GR
IDFA4E-23-L
IDFA4E-23-R
IDFA4E-23-T
IDFA6E-20
IDFA6E-20-A
IDFA6E-20-ACLT
IDFA6E-20-HT
IDFA6E-23
IDFA6E-23-A
IDFA6E-23-AL
IDFA6E-23-C
IDFA6E-23-CKR
IDFA6E-23-CLRT
IDFA6E-23-G
IDFA6E-23-GR
IDFA6E-23-K
IDFA6E-23-L
IDFA6E-23-LR
IDFA6E-23-T
IDFA8E-23
IDFA8E-23-A
IDFA8E-23-C
IDFA8E-23-K
IDFA8E-23-L
IDFA8E-23-R
IDFA8E-23-RT
IDFA8E-23-T
IDFA8E-23-V
IDFA11E-23
IDFA11E-23-A
IDFA11E-23-C