Refrigerated Air Dryer, Refrigerant R407C (HFC) IDF100F/125F/150F Series Specifications – Máy Sấy Khí SMC
Air-cooled
IDF1□□F-30 Series (air-cooled) external appearance
IDF1□□F-30 Series (air-cooled) JIS symbol
– | Model | |||||
---|---|---|---|---|---|---|
Specifications | IDF100F-30 | IDF125F-30 | IDF150F-30 | |||
Operating range*3 | Applicable fluid | Compressed Air | ||||
Inlet air temperature (°C) | 5 to 60 | |||||
Inlet air pressure (MPa) | 0.15 to 1.0 | |||||
Ambient temperature (humidity) (°C) | 2 to 45 (Relative humidity of 85% or less) | |||||
*4 | Air flow capacity m3/min | Standard condition (ANR)*1 | 50 Hz | 16 | 20.1 | 25 |
60 Hz | 18.8 | 23.7 | 30 | |||
Compressor intake condition*2 | 50 Hz | 17 | 21 | 27 | ||
60 Hz | 20 | 25 | 32 | |||
Inlet air pressure (MPa) | 0.7 | |||||
Inlet air temperature (°C) | 40 | |||||
Ambient temperature (°C) | 32 | |||||
Outlet air pressure dew point (°C) | 10 | |||||
Exhaust heat from condenser (50/60 Hz) (kW) | 8.0/9.0 | 10.0/11.5 | 12.0/15.0 | |||
Dryer outlet air temperature (°C) | 37 | |||||
Power supply voltage (frequency) | Three-phase: 200 V AC (50 Hz) / 200/220 V AC (60 Hz) | |||||
Electric specifications | Power consumption*5 (50/60 Hz) (kW) | 2.9/3.5 | 4.0/4.7 | 4.0/4.8 | ||
Operating current*5(50/60 Hz) (A) | 10.5/11.5 | 15.4/15.6 | 15.7/16.0 | |||
Applicable circuit breaker capacity*6 (A) (Sensitivity current of 30 mA) |
30 | |||||
Refrigerant | R407C (HFC) | |||||
Refrigerant charge (kg) | 1.1 | 1.6 | 1.98 | |||
Auto drain | Heavy-duty auto drain (normally open) | |||||
Port size | R2 | JIS flange 65A/10K | JIS flange 80A/10K | |||
Weight (kg) | 245 | 270 | 350 | |||
Coating color | Body panel: urban white 1 Base: urban gray 2 |
|||||
Applicable compressor output (Reference) (kW) For screw type |
100 | 125 | 150 |
*1: Indicates the air flow capacity under the standard condition (ANR) (atmospheric pressure 20°C, relative humidity 65%).
*2: Indicates the air flow capacity converted by the compressor intake condition (atmospheric pressure 32°C, relative humidity 75%).
*3: The operating range does not guarantee use at rated air flow capacity.
*4: If the operating conditions differ from the rating, select the model referring to “Model Selection” in the manufacturer’s catalog.
*5: These are reference values under the rated conditions and are not guaranteed. Do not use these as thermal setting values, etc.
*6: Products without option R do not come with a circuit breaker. Purchase a circuit breaker separately.
IDF100F-30-1
IDF100F-30-2
IDF100F-30-3
IDF100F-30-C
IDF100F-30-CKPRV
IDF100F-30-CPRV
IDF100F-30-CR
IDF100F-30-CRV
IDF100F-30-CV
IDF100F-30-K
IDF100F-30-KPRV
IDF100F-30-KRV
IDF100F-30-KV
IDF100F-30-KW4
IDF100F-30-P
IDF100F-30-PR
IDF100F-30-PRV
IDF100F-30-PV
IDF100F-30-R
IDF100F-30-R1
IDF100F-30-R2
IDF100F-30-RV
IDF100F-30-RW4
IDF100F-30-V
IDF100F-30-VW4
IDF100F-30-VW5
IDF100F-30-W4
IDF100F-30-W5
IDF125F-30-1
IDF125F-30-2
IDF125F-30-3
IDF125F-30-C
IDF125F-30-C1
IDF125F-30-C2
IDF125F-30-CV1
IDF125F-30-K
IDF125F-30-PR
IDF125F-30-R
IDF125F-30-R1
IDF125F-30-R3
IDF125F-30-V
IDF125F-30-VW5
IDF125F-30-W4
IDF150F-30-1
IDF150F-30-2
IDF150F-30-3
IDF150F-30-C
IDF150F-30-CPR
IDF150F-30-CPR3
IDF150F-30-CR
IDF150F-30-CW4
IDF150F-30-K
IDF150F-30-KW4
IDF150F-30-R
IDF150F-30-R1
IDF150F-30-V
IDF150F-30-W4
IDF150F-30-W5