Refrigerant R134a (HFC) Standard Temperature Air Inlet, IDFB□E Series Specifications – Máy Sấy Khí SMC
IDFB□E Series external appearance
*The external appearance images are representative images.
JIS symbol
Standard specifications
Specifications | Model | ||||
---|---|---|---|---|---|
Standard-temperature air inlet | |||||
IDFB3E | IDFB4E | IDFB6E | |||
Operating range*3 | Applicable fluid | Compressed Air | |||
Inlet air temperature (°F [°C]) | 41 to 122 (5 to 50) | ||||
Inlet air pressure (psi [MPa]) | 22 (0.15) to 150 (1.0) | ||||
Ambient temperature (°F [°C]) | 36 to 104 (2 to 40), Relative humidity of 85% or less | ||||
*4 | Air flow capacity SCFM*1, *2 (m3/h [ANR]) |
Outlet pressure dew point 37°F (2.8°C) | 10 (17) | 15 (25) | 25 (43) |
Outlet pressure dew point 45°F (7.2°C) | 11 (19) | 16 (27) | 26 (45) | ||
Outlet pressure dew point 50°F (10°C) | 12 (20) | 17 (28) | 28 (47) | ||
Operating pressure (psi [MPa]) | 100 (0.7) | ||||
Inlet air temperature (°F [°C]) | 100 (37.8) | ||||
Ambient temperature (°F [°C]) | 100 (37.8) | ||||
Electric specifications | Power supply voltage (frequency) | Single-phase 115 V AC (Voltage fluctuation ±10%) 60 Hz | |||
Operating current*5 (A) | 2.7 | 3.0 | 3.0 | ||
Power consumption*5 (W) | 240 | 260 | 260 | ||
Applicable circuit breaker capacity*6 (A) (Sensitivity current of 30 mA) |
15 | ||||
Condenser | Forced air-cooled | ||||
Refrigerant | R134a (HFC) | ||||
Refrigerant charge (oz [g]) | 6.3 (180) | 7.0 (200) | 8.1 (230) | ||
Thread symbol and size | Symbol N | NPT3/8 female | NPT1/2 (female) | NPT3/4 (female) | |
Symbol Nil | Rc3/8 (female) With Rc conversion adapter |
Rc1/2 (female) With Rc conversion adapter |
Rc3/4 (female) With Rc conversion adapter |
||
Drain tube outer diameter | Symbol N | 3/8 inch | |||
Symbol Nil | 10 mm | ||||
Coating color | Urban white 1 | ||||
Weight (lbs [kg]) | 40 (18) | 55 (25) | 57 (26) | ||
Compliant standards | UL, CSA |
Specifications | Model | ||||
---|---|---|---|---|---|
Standard-temperature air inlet | |||||
IDFB8E | IDFB11E | IDFB15E | |||
Operating range*3 | Applicable fluid | Compressed Air | |||
Inlet air temperature (°F [°C]) | 41 to 122 (5 to 50) | ||||
Inlet air pressure (psi [MPa]) | 22 (0.15) to 150 (1.0) | ||||
Ambient temperature (°F [°C]) | 36 to 104 (2 to 40), Relative humidity of 85% or less | ||||
*4 | Air flow capacity SCFM*1, *2 (m3/h [ANR]) |
Outlet pressure dew point 37°F (2.8°C) | 41 (70) | 59 (100) | 71 (120) |
Outlet pressure dew point 45°F (7.2°C) | 43 (74) | 62 (106) | 80 (136) | ||
Outlet pressure dew point 50°F (10°C) | 45 (77) | 65 (110) | 86 (147) | ||
Operating pressure (psi [MPa]) | 100 (0.7) | ||||
Inlet air temperature (°F [°C]) | 100 (37.8) | ||||
Ambient temperature (°F [°C]) | 100 (37.8) | ||||
Electric specifications | Power supply voltage (frequency) | Single-phase 115 V AC (Voltage fluctuation ±10%) 60 Hz | |||
Operating current*5 (A) | 3.5 | 6.5 | 7.5 | ||
Power consumption*5 (W) | 310 | 550 | 750 | ||
Applicable circuit breaker capacity*6 (A) (Sensitivity current of 30 mA) |
15 | ||||
Condenser | Forced air-cooled | ||||
Refrigerant | R134a (HFC) | ||||
Refrigerant charge (oz [g]) | 9.5 (270) | 10.2 (290) | 12.0 (340) | ||
Thread symbol and size | Symbol N | NPT3/4 (female) | NPT1 female | ||
Symbol Nil | Rc3/4 (female) With Rc conversion adapter |
Rc1 (female) With Rc conversion adapter |
|||
Drain tube outer diameter | Symbol N | 3/8 inch | |||
Symbol Nil | 10 mm | ||||
Coating color | Urban white 1 | ||||
Weight (lbs [kg]) | 64 (29) | 73 (33) | 110 (50) | ||
Compliant standards | UL, CSA |
*1: Indicates the air flow capacity under ANR (atmospheric pressure 68°F (20°C), relative humidity 65%).
*2: Indicates the air flow capacity for each outlet pressure dew point.
*3: The operating range does not guarantee use at rated air flow capacity.
*4: If the operating conditions differ from the rating, select the model referring to “Model Selection” in the manufacturer’s catalog.
*5: These are reference values under the rated conditions and are not guaranteed. Do not use these as thermal setting values, etc.
*6: Products without option R do not come with a circuit breaker. Purchase a circuit breaker separately.
*7: When a short-term interruption of the power supply (including momentary interruption) occurs in this equipment, the restarting of normal operations may require some time or may be impossible due to the operation of protective devices even after the supply of power returns.
IDFB3E-11-A
IDFB3E-11N
IDFB3E-11N-A
IDFB3E-11N-S
IDFB4E-11
IDFB4E-11-RS
IDFB4E-11N
IDFB4E-11N-ARTV
IDFB6E-11
IDFB6E-11N
IDFB6E-11N-A
IDFB6E-11N-KT
IDFB8E-11
IDFB8E-11-KT
IDFB15E-11
IDFB15E-11-R
IDFB15E-11N-T