Download
Pressure Sensor For General Fluids PSE560 Series Details – Cảm Biến Áp Suất SMC
Pressure Sensor For General Fluids PSE560 Series product image
Pressure Sensor For General Fluids PSE560 Series Specifications
Model Number Notation
Model number example
Model | PSE560 (Positive pressure) | PSE561 (Vacuum pressure) | PSE563 (Compound pressure) | PSE564 (Positive pressure) |
---|---|---|---|---|
Rated pressure range | 0 to 1 MPa | 0 to -101 kPa | -100 to 100 kPa | 0 to 500 kPa |
Extended analog output range | -0.1 to 0 MPa | 10.1 to 0 kPa | – | -50 to 0 kPa |
Pressure resistance | 1.5 MPa | 500 kPa | 500 kPa | 750 kPa |
Model | PSE56□-□ | PSE56□-□-28 | |
---|---|---|---|
Applicable fluid | Liquid or gas that will not corrode or attack SUS316L | ||
Power supply voltage | 12 to 24 V DC ±10%, Ripple (p-p) 10% or less (with reverse connection protection) | ||
Current Consumption | 10 mA or less | – | |
Output specifications | Analog output 1 to 5 V (within rated pressure range) 0.6 to 1 V (within extended analog output range) Output impedance: approx. 1 kΩ |
Analog output 4 to 20 mA (within rated pressure range) Maximum load impedance: 500 Ω or less (at 24 V), 100 Ω or less (at 12 V) |
|
Accuracy (ambient temperature of 25°C) | ±1% F.S. (within rated pressure range), ±3% F.S. (within extended analog output range) | ||
Linearity | ±0.5% F.S. | ||
Repeat accuracy | ±0.2% F.S. | ||
Power supply voltage effect | ±0.3% F.S. | ||
Environmental resistance | Enclosure | IP65 | |
Operating temperature range | During operation: -10 to 60°C, During storage: -20 to 70°C (No condensation or freezing) | ||
Operating Humidity Range | During operation, storage: 35 to 85% RH (No condensation) | ||
Withstand Voltage | 250 V AC for 1 min. between terminals and housing | ||
Insulation Resistance | 50 MΩ or more (50 V DC, measured via megohmmeter) between terminals and housing | ||
Temperature characteristics | ±2% F.S. (0 to 50°C: 25°C reference), ±3% F.S. (-10 to 60°C: 25°C reference) | ||
Sensor cable | PSE56□-□: Oilproof vinyl heavy-duty cable with air tubing, 3 cores ø5.1 (5.1‑mm diameter) 3 m, Conductor area: 0.2 mm2 Insulator O.D.: 1.12 mm PSE56□-□-28: Oilproof vinyl heavy-duty cable with air tubing, 2 cores ø5.1 (5.1‑mm diameter) 3 m, Conductor area: 0.2 mm2 Insulator O.D.: 1.12 mm |
||
Standard | CE UL/CSA (E216656) |
ZS-31-X186
ZS-31-X188
ZS-31-X189
PSE560-01
PSE560-01-28
PSE560-01-28-C2
PSE560-01-C2
PSE560-02
PSE560-02-28
PSE560-02-28-C2
PSE560-02-C2
PSE560-A2
PSE560-A2-28
PSE560-A2-28-C2
PSE560-A2-C2
PSE560-B2
PSE560-B2-28
PSE560-B2-28-C2
PSE560-B2-C2
PSE560-C01
PSE560-C01-28
PSE561-01-28
PSE561-01-28-C2
PSE561-01-C2
PSE561-02
PSE561-02-28
PSE561-02-28-C2
PSE561-02-C2
PSE561-A2
PSE561-A2-28
PSE561-A2-28-C2
PSE561-A2-C2
PSE561-B2
PSE561-B2-28
PSE561-B2-28-C2
PSE561-B2-C2
PSE561-C01
PSE561-C01-28
PSE561-C01-28-C2
PSE561-C01-C2
PSE561-N01
PSE561-N01-28
PSE561-N01-C2
PSE561-N02
PSE561-N02-28
PSE561-N02-28-C2
PSE563-02-28-C2
PSE563-02-C2
PSE563-A2
PSE563-A2-28
PSE563-A2-28-C2
PSE563-A2-C2
PSE563-B2
PSE563-B2-28
PSE563-B2-28-C2
PSE563-B2-C2
PSE563-C01
PSE563-C01-28
PSE563-C01-28-C2
PSE563-C01-C2
PSE563-N01
PSE563-N01-28
PSE563-N01-28-C2
PSE563-N01-C2
PSE563-N02
PSE563-N02-28
PSE563-N02-28-C2
PSE563-N02-C2
PSE564-01-28
PSE564-01-28-C2
PSE564-01-C2
PSE564-02
PSE564-02-28
PSE564-02-28-C2
PSE564-02-C2
PSE564-A2
PSE564-A2-28
PSE564-A2-28-C2
PSE564-A2-C2
PSE564-B2
PSE564-B2-28
PSE564-B2-C2
PSE564-C01
PSE564-C01-28
PSE564-C01-28-C2
PSE564-C01-C2
PSE564-N01
PSE564-N01-28
PSE564-N01-28-C2
PSE564-N01-C2
PSE564-N02
PSE564-N02-28
PSE564-N02-28-C2
PSE564-N02-C2