Valve Specifications | Series | VQ20 | VQ30 | |
---|---|---|---|---|
Valve Construction | Pilot operated 2-port poppet type | |||
Usable Fluids | Air*1 | |||
Ambient Temperature and Operating Fluid Temperature | -10 to 50°C *2 | |||
Lubrication | Not required | |||
Manual Operation | Locking type (tool required)*3 | |||
Impact Resistance / Vibration Resistance | 150 / 30 m/s2 *4 | |||
Enclosure | Dust-proof*5 | |||
Internal leakage cm3/min | 15 or less | |||
External leakage cm3/min | 15 or less | |||
Mounting Orientation | Free | |||
Weight | 46 g | 80 g | ||
Electrical Specifications | Coil Rated Voltage | 12 V DC, 24 V DC, 100 V AC, 110 V AC, 200 V AC, 220 V AC | ||
Allowable Voltage Fluctuation | ±10% of rated voltage | |||
Coil Insulation Type | Class B or equivalent | |||
Power Consumption | DC (with power-saving circuit) | Inrush: 2.9 W Holding: 0.6 W | ||
DC (without power-saving circuit) | 2.9 W | |||
AC | 2 VA | |||
Electrical Entry | Grommet, DIN terminal |
- *1This product is for dry air. Use in clean air and take care that drain and oil content do not get into this product.
- *2Use dry air when operating at low temperatures and with no condensation.
- *3Manual operation is available for DIN terminal type only.
- *4Vibration resistance: No malfunction occurred in 1 sweep test between 8.3 and 2,000 Hz. The test was performed in both energized and de-energized states in the axial and right angle directions of the main valve/armature. (Initial value)
Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value) - *5DIN terminal type supports dust-proof and blow-proof (IP65) performance.
VQ21A1-1G-C6-F
VQ21A1-1G-C6-F-X2
VQ21A1-1G-C6-F-X23
VQ21A1-1G-C6-L
VQ21A1-1G-C6-LF
VQ21A1-1G-C6-Q
VQ21A1-1G-C6-X2
VQ21A1-1G-C8
VQ21A1-1G-C8-F
VQ21A1-1G-C8-F-Q
VQ21A1-1G-C8-F-X2
VQ21A1-1G-C8-F-X5
VQ21A1-1G-C8-F-X23
VQ21A1-1G-C8-L
VQ21A1-1G-C8-LF
VQ21A1-1G-C8-X2
VQ21A1-1GZ-C6
VQ21A1-1GZ-C6-F
VQ21A1-1GZ-C6-F-Q
VQ21A1-1GZ-C6-F-X2
VQ21A1-1Y-C6-LF
VQ21A1-1Y-C6-Q
VQ21A1-1Y-C6-X23
VQ21A1-1Y-C6-X23-Q
VQ21A1-1Y-C8
VQ21A1-1Y-C8-F
VQ21A1-1Y-C8-F-Q
VQ21A1-1Y-C8-L
VQ21A1-1YB-C6
VQ21A1-1YB-C6-F
VQ21A1-1YB-C8
VQ21A1-1YB-C8-F
VQ21A1-1YO-C6-F
VQ21A1-1YO-C6-LF
VQ21A1-1YO-C8
VQ21A1-1YO-C8-F
VQ21A1-1YOB-C8-F
VQ21A1-1YZ-C6
VQ21A1-1YZ-C6-F
VQ21A1-1YZ-C6-F-Q
VQ31A1-1G-C10-F
VQ31A1-1G-C10-F-X2
VQ31A1-1G-C10-X2
VQ31A1-1G-C10-X23
VQ31A1-1G-C12
VQ31A1-1G-C12-F
VQ31A1-1G-C12-F-X2
VQ31A1-1G-C12-X2
VQ31A1-1GZ-C10
VQ31A1-1GZ-C10-F
VQ31A1-1GZ-C10-F-X2
VQ31A1-1GZ-C10-F-X23
VQ31A1-1GZ-C10-X2
VQ31A1-1GZ-C12
VQ31A1-1GZ-C12-F
VQ31A1-1GZ-C12-F-X2
VQ31A1-1GZ-C12-X5
VQ31A1-1Y-C10
VQ31A1-1Y-C10-F
VQ31A1-1Y-C10-F-X2
VQ31A1-1Y-C12
VQ31A1-1Y-C12-F
VQ31A1-1Y-C12-F-Q
VQ31A1-1Y-C12-F-X2
VQ31A1-1YB-C10
VQ31A1-1YZB-C12-F
VQ31A1-1YZB-C12-F-Q
VQ31A1-1YZB-C12-F-X5
VQ31A1-1YZB-C12-Q
VQ31A1-2G-C10
VQ31A1-2G-C10-F
VQ31A1-2G-C10-F-X2
VQ31A1-2G-C10-Q
VQ31A1-2G-C10-X2
VQ31A1-2G-C12
VQ31A1-2G-C12-F
VQ31A1-2G-C12-F-X2
VQ31A1-2GZ-C10
VQ31A1-2GZ-C10-F
VQ31A1-2GZ-C10-F-X2
VQ31A1-2GZ-C10-F-X5
VQ31A1-2GZ-C10-F-X23