Model | ISE70 | ISE71 | ||
---|---|---|---|---|
Applicable Fluid | Air, non-corrosive gas, non-flammable gas | |||
Pressure Specifications | Rated Pressure Range | 0 to 1.000 MPa | 0 to 1.600 MPa | |
Display / Set Pressure Range | -0.105 to 1.050 MPa | -0.105 to 1.680 MPa | ||
Display / Minimum Set Unit | 0.001 MPa | 0.001 MPa | ||
Pressure-resistant | 1.5 MPa | 2.4 MPa | ||
Power Supply Specifications | Power Supply Voltage | When Using as Switch Output Equipment: | 12 to 24 V DC ±10% and power supply ripple: 10% or less | |
When Using as IO-Link Device: | 18 to 30 V DC including ripple (p-p) of ±10% | |||
Current Consumption | 35 mA or less | |||
Protection | Reverse connection protection | |||
Accuracy | Display Accuracy | ±2%F.S. ±1 digit (at ambient temperature of 25 ±3°C) | ||
Repeatability | ±0.5%F.S. | |||
Temperature Characteristics | ±2%F.S. (25°C reference) | |||
Switch Output When SIO Mode is Output Specifications “AB” or Output Specifications “L2” |
Output Type | NPN open collector output or PNP open collector output is selected | ||
Output Mode | Hysteresis, Window comparator, Error output, Output OFF | |||
Switching Operation | Forward rotation output, Reverse rotation output | |||
Maximum Load Current | 80 mA | |||
Maximum Applied Voltage | 30 V (at NPN output) | |||
Internal Voltage Drop (Residual Voltage) | 1.5 V or less (with load current of 80 mA) | |||
Delay time*1) | 1.5 ms or less, variable with 0 to 60 sec / 0.01 sec step | |||
Hysteresis | Hysteresis Mode | Variable from 0*2) | ||
Window Comparator Mode | ||||
Short-circuit Protection | Equipment | |||
Display | Unit*3) | MPa, kPa, kgf/cm2, bar, psi | ||
Display Method | LCD | |||
Sample Screen | 3 screens (main screen, sub screen × 2) | |||
Display Color | Main screen: red/green, Sub screen: orange | |||
Display Digit | Main screen: 4-digit 7-segment, Sub screen: 4-digit (upper 1-digit: 11-segment, others: 7-segment) | |||
Operation Indicator Light | Lights up when switch output is turned ON, OUT1, OUT2: orange | |||
Digital Filter*4) | 0 to 30 sec, variable with 0.01 sec step | |||
Environmental Resistance | Protection Grade | IP67 | ||
Withstand voltage | 1,000 V AC for 1 min. between terminals and housing | |||
Insulation Resistance | 50 MΩ or more (500 V DC measured via ohmmeter) between terminals and housing | |||
Operating Temperature Range | Operating: 0 to 50°C, Stored: -10 to +60°C (no condensation or freezing) | |||
Operating Humidity Range | Operating and stored: 35 to 85% RH (no condensation) | |||
Standard | UL/CSA (E216656), CE | |||
Piping Specifications | Pipe Connection Port Diameter | Rc1/4, NPT1/4, G1/4 | ||
Wetted Parts Material | Sensor pressure receiving area: Silicone Piping port part: C3604 (Electroless nickel plated), O-ring: HNBR |
|||
Weight | Main Body | Pipe Connection Port Diameter Rc1/4 | 153 g | |
Pipe Connection Port Diameter NPT1/4 | 152 g | |||
Pipe Connection Port Diameter G1/4 | 150 g | |||
Lead Wire With Connector | 139 g | |||
Communication Specifications (at IO-Link Mode) |
IO-Link Type | Device | ||
IO-Link Version | V1.1 | |||
Communication Speed | COM2 (38.4 kbps) | |||
Configuration File | IODD file*5) | |||
Minimum Cycle Type | 2.3 ms | |||
Process Data Length | Input Data: 2 byte, Output Data: 0 byte | |||
On Request Data Communication | Compatible | |||
Data Storage Function | Compatible | |||
Event Function | Compatible | |||
Vendor ID | 131 (0 × 0083) |
*1) Value without digital filter (0 ms).
*2) If the applied voltage fluctuates around the set value, the hysteresis must be set to a value more than the width of the fluctuations or chattering will occur.
*3) This can be set when using a product with a unit switching function.
When there is no unit switching function, only MPa/kPa can be selected.
*4) 90% response time to step input.
*5) Refer to the catalog for setting file.
*6) Products with small scratches, smears or variations in display color and brightness, etc., that do not affect the performance will be verified as conforming products.
Product Features
Install the switch using a wrench and after installation, fix the body by hand and rotate the display in a direction that makes it easy to see
ZS-50-B
ISE70-02-AB
ISE70-02-AB-A
ISE70-02-AB-L
ISE70-02-AB-LA
ISE70-02-AB-M
ISE70-02-AB-MA
ISE70-02-AB-ML
ISE70-02-AB-MLA
ISE70-02-AB-MLB
ISE70-02-AB-MS
ISE70-02-AB-MSA
ISE70-02-AB-MSB
ISE70-02-AB-S
ISE70-02-AB-SA
ISE70-02-AB-SK
ISE70-02-L2
ISE70-02-L2-A
ISE70-02-L2-L
ISE70-02-L2-LA
ISE70-02-L2-LAK
ISE70-02-L2-LK
ISE70-02-L2-M
ISE70-02-L2-MA
ISE70-02-L2-ML
ISE70-02-L2-MLY
ISE70-02-L2-MS
ISE70-02-L2-MSA
ISE70-02-L2-MSB
ISE70-02-L2-MSK
ISE70-02-L2-MST
ISE70-02-L2-MSY
ISE70-02-L2-S
ISE70-02-L2-SA
ISE70-02-L2-SB
ISE70-02-L2-SBK
ISE70-02-L2-SK
ISE70-02-L2-SY
ISE70-02-L2-Y
ISE70-F02-67-ML
ISE70-F02-AB
ISE70-F02-AB-A
ISE70-F02-AB-LA
ISE70-F02-AB-M
ISE70-F02-AB-S
ISE70-F02-AB-SA
ISE70-F02-AB-SAK
ISE70-F02-L2
ISE70-F02-L2-A
ISE70-F02-L2-K
ISE70-F02-L2-L
ISE71-02-AB-MLA
ISE71-02-L2
ISE71-02-L2-L
ISE71-02-L2-LA
ISE71-02-L2-LBK
ISE71-02-L2-M
ISE71-02-L2-MB
ISE71-02-L2-ML
ISE71-02-L2-MLB
ISE71-02-L2-MLK
ISE71-02-L2-MS
ISE71-02-L2-MSA
ISE71-02-L2-S
ISE71-02-L2-SA
ISE71-02-L2-SBK
ISE71-02-L2-T
ISE71-F02-AB-M
ISE71-F02-AB-MLBK
ISE71-F02-L2
ISE71-F02-L2-K
ISE71-F02-L2-L
ISE71-F02-L2-M
ISE71-F02-L2-ML
ISE71-F02-L2-MS
ISE71-F02-L2-MST
ISE71-F02-L2-S
ISE71-N02-L2-LK
ISE71-N02-L2-ML
ISE70-F02-L2-MLA
ISE70-F02-L2-MLK
ISE70-F02-L2-MS
ISE70-F02-L2-MSA
ISE70-F02-L2-S
ISE70-F02-L2-SY
ISE70-F02-L2-Y
ISE70-N02-AB
ISE70-N02-AB-A
ISE70-N02-AB-LA
ISE70-N02-AB-S
ISE70-N02-AB-SA
ISE70-N02-L2
ISE70-N02-L2-BK
ISE70-N02-L2-K
ISE70-N02-L2-L
ISE70-N02-L2-LA
ISE70-N02-L2-LB
ISE70-N02-L2-M
ISE70-N02-L2-MA