Download
Direct Operated 3 Port Solenoid Valve VX31/VX32/VX33 Series For Air, Water, Oil and Steam Specifications – Van điện từ khí nén SMC
For Air / Single Unit
For air, single unit (non-leak / medium vacuum) external appearance
Fluid and Ambient Temperature
- Fluid temperature (no symbol, G): AC -10* to +60°C / DC -10* to +60°C
- Fluid temperature (V/M): AC -10* to +40°C / DC -10* to +40°C
- Ambient temperature: AC -20 to +60°C / DC -20 to +40°C
*Dew point temperature: -10°C or less
Valve Leakage Amount (Internal Leakage / External Leakage) Seal Material: NBR, FKM
- Maximum operating pressure differential (no greater than 0 to 1 MPa): air 1 cm3/min or less, non-leak, medium vacuum* 10-6 Pa·m3/sec or less
- Maximum operating pressure differential (1 MPa or higher): air 2 cm3/min or less, non-leak, medium vacuum* 10-6 Pa·m3/sec or less
*Leakage amount for options V and M (10-6 Pa·m3/sec) is for a pressure differential of 0.1 MPa.
For Air / Manifold
For air, manifold (non-leak / medium vacuum) external appearance
Fluid and Ambient Temperature
- Fluid temperature (no symbol): AC -10* to +60°C / DC -10* to +60°C
- Fluid temperature (V): AC -10* to +40°C / DC -10* to +40°C
- Ambient temperature: AC -20 to +60°C / DC -20 to +40°C
*Dew point temperature: -10°C or less
Valve Leakage Amount (Internal Leakage / External Leakage) Seal Material: NBR, FKM
- Maximum operating pressure differential (no greater than 0 to 1 MPa): air 1 cm3/min or less, non-leak, medium vacuum* 10-6 Pa·m3/sec or less
- Maximum operating pressure differential (1 MPa or higher): air 2 cm3/min or less, non-leak, medium vacuum* 10-6 Pa·m3/sec or less
*Leakage amount for option V (10-6 Pa·m3/sec) is for a pressure differential of 0.1 MPa.
For Water / Single Unit
For water / single unit external appearance
Fluid and Ambient Temperature
- Fluid temperature (no symbol, G, H): AC 1 to 60°C / DC 1 to 40°C
- Fluid temperature (E/P): AC 1 to 99°C / DC NA
- Ambient temperature: AC -20 to +60°C / DC -20 to +40°C
*No freezing
Valve Leakage Amount (Internal Leakage / External Leakage) Seal Material: NBR, FKM, EPDM
- Maximum operating pressure differential (no more than 0 to 1 MPa): water 0.1 cm3/min or less
- Maximum operating pressure differential (1 MPa or more): water 0.2 cm3/min or less
For Oil / Single Unit
For oil / single unit external appearance
Fluid and Ambient Temperature
- Fluid temperature (A/H): AC -5* to +60°C / DC -5* to +40°C
- Fluid temperature (D/N): AC -5* to +120°C / DC NA
- Ambient temperature: AC -20 to +60°C / DC -20 to +40°C
*Kinematic viscosity: 50 mm2/s or less
Valve Leakage Amount (Internal Leakage / External Leakage) Seal Material: FKM
- Maximum operating pressure differential (no more than 0 to 1 MPa): oil 0.1 cm3/min or less
- Maximum operating pressure differential (1 MPa or more): oil 0.2 cm3/min or less
*Lists information for only some products.
VX31/VX32/VX33 Series Common Specifications
Standard Specification
Valve Specifications | Valve Structure | Direct operated poppet | |
---|---|---|---|
Withstand Pressure MPa | 3.0 | ||
Body Material | C37, SUS | ||
Seal Materials | NBR, FKM, EPDM, PTFE, FFKM | ||
Enclosure | Dustproof, jetproof (IP65)* | ||
Environment | Locations without corrosive or explosive gases | ||
Coil Specifications | Rated Voltage | AC (Class B: Built-In Full Wave Rectifier Type) | 100 V AC, 200 V AC, 110 V AC, 220 V AC, 230 V AC, 240 V AC, 48 V AC |
AC (Class H) | |||
DC | 24 V DC, 12 V DC | ||
Allowable Voltage Fluctuation | ±10% of rated voltage | ||
Allowable Leakage Voltage | AC (Class B: Built-In Full Wave Rectifier Type) | 5% or less of rated voltage | |
AC (Class H) | 20% or less of rated voltage | ||
DC | 2% or less of rated voltage | ||
Coil Insulation Type | Class B, class H |
*Electrical entry, grommet with surge voltage suppressor (GS) has an IP40 rating. See SMC catalog for information on protection grades. Contact the SMC support center regarding use in locations that require water resistance.
Solenoid Coil Specifications
DC Specification
Model | Apparent Power (W) | Temperature Increase (°C)* |
---|---|---|
VX31 | 4.5 | 45 |
VX32 | 7 | 45 |
VX33 | 10.5 | 60 |
*Ambient temperature is 20°C. Value is for when rated voltage is applied.
AC Specification (Class B: Built-In Full Wave Rectifier Type)
Model | Apparent Power (VA)* | Temperature Increase (°C)* |
---|---|---|
VX31 | 7 | 55 |
VX32 | 9.5 | 60 |
VX33 | 12 | 65 |
*AC (class B) employs a rectifier circuit, so there is no apparent power fluctuations caused by frequency and inrush/holding.
*Ambient temperature is 20°C. Value is for when rated voltage is applied.
AC Specification (Class H)
Model | – | Frequency (Hz) | Temperature Increase (°C)* | |
---|---|---|---|---|
Frequency (Hz) | Inrush | Holding | ||
VX31 | 50 | 33 | 14 | 65 |
60 | 28 | 12 | 60 | |
VX32 | 50 | 65 | 33 | 100 |
60 | 55 | 27 | 95 | |
VX33 | 50 | 94 | 50 | 120 |
60 | 79 | 41 | 115 |
*Ambient temperature is 20°C. Value is for when rated voltage is applied.
VX3110-01-2DLR1-B
VX3110-01-2DR1
VX3110-01-2GR1-B
VX3110-01-2TR1
VX3110-01-5C1
VX3110-01-5D1-B
VX3110-01-5DL1
VX3110-01-5DL1-B
VX3110-01-5DO1
VX3110-01-5DZ1
VX3110-01-5DZ1-B
VX3110-01-5G1
VX3110-01-5G1-B
VX3110-01-5GS1-B
VX3110-01-5T1-B
VX3110-01-5TL1
VX3110-01-5TL1-B
VX3220-02-1DOR1-B
VX3220-02-1DR1
VX3220-02-1TLR1
VX3220-02-1TR1-B
VX3220-02-2CR1-B
VX3220-02-2DLR1-B
VX3220-02-2DR1
VX3220-02-2DR1-B
VX3220-02-2GR1-B
VX3220-02-3DLR1
VX3220-02-3GR1
VX3220-02-4DLR1
VX3220-02-4DR1
VX3220-02-4GR1
VX3220-02-4GR1-B
VX3220-02-5DO1-B
VX3320-02-1TLR1-B
VX3320-02-2GR1-B
VX3320-02-4DR1-B
VX3320-02-4TLR1-B
VX3320-02-5C1-B
VX3320-02-5D1-B
VX3320-02-5DL1
VX3320-02-5DZ1
VX3320-02-5DZ1-B
VX3320-02-5G1-B
VX3320-02-5GS1-B
VX3320-02-5TL1
VX3320-02-5TZ1
VX3320-02F-4DR1
VX3320-02F-5DL1-B
VX3320-02N-2GR1