Download
Specifications of Digital Flow Switch for Air PF2A Series – Cảm Biến Áp Suất SMC
External appearance of PF2A7 Series (Integrated display type)
External appearance of PF2A5 Series (Remote type / sensor part)
Specifications of PF2A7
Model | PF2A710 | PF2A750 | PF2A711 | PF2A721 | PF2A751 | |
---|---|---|---|---|---|---|
Measured fluid | Air, nitrogen | |||||
Flow rate measurement range | 0.5 to 10.5 L/min | 2.5 to 52.5 L/min | 5 to 105 L/min | 10 to 210 L/min | 25 to 525 L/min | |
Set flow rate range | 0.5 to 10.5 L/min | 2.5 to 52.5 L/min | 5 to 105 L/min | 10 to 210 L/min | 25 to 525 L/min | |
Rated flow range | 1 to 10 L/min | 5 to 50 L/min | 10 to 100 L/min | 20 to 200 L/min | 50 to 500 L/min | |
Minimum Unit Setting | 0.1 L/min | 0.5 L/min | 1 L/min | 2 L/min | 5 L/min | |
Accumulated pulse flow rate exchange value (pulse width: 50 ms) | 0.1 L/pulse | 0.5 L/pulse | 1 L/pulse | 2 L/pulse | 5 L/pulse | |
Display unit *1, 2) | Instantaneous flow rate | L/min, CFM × 10^-2 | L/min, CFM x 10^-1 | |||
Accumulated flow rate | L, ft^3 × 10^-1 | |||||
Operating Fluid Temperature | 0 to 50°C | |||||
Accuracy *3) | ±5% F.S. | |||||
Repeatability | ±1% F.S. | ±2% F.S. | ||||
Temperature characteristics | ±3% F.S. (15 to 35°C, 25°C reference), ±5% F.S. (0 to 50°C, 25°C reference) | |||||
Current Consumption | 150 mA or less | 160 mA or less | 170 mA or less | |||
Weight *4) | 250 g | 290 g | ||||
Port size (Rc, NPT, G) | 1/8, 1/4 | 3/8 | 1/2 | |||
Detection Type | Heat type | |||||
Indicator light | 3-digit 7-segment LED | |||||
Operating Pressure Range | -50 kPa to 0.5 MPa | -50 kPa to 0.75 MPa | ||||
Withstand pressure | 1.0 MPa | |||||
Accumulated Flow Rate Range *5) | 0 to 999,999 L | |||||
Output Specifications *6) | Switch output | NPN open collector: Maximum load current: 80 mA, Internal voltage drop: 1 V or less (with load current of 80 mA), Maximum applied voltage: 30 V, 2 outputs | ||||
PNP open collector maximum load current: 80 mA, internal voltage drop: 1.5 V or less (with load current of 80 mA), 2 outputs | ||||||
Accumulated pulse output | NPN or PNP open collector (same as switch output) | |||||
Indicator light | Light up when output is turned ON, OUT1: green, OUT2: red | |||||
Response Time | 1 s or less | |||||
Hysteresis | Hysteresis mode: Variable (It can be set from 0) Window comparator mode *7): Fixed (3 digits) | |||||
Power supply voltage | 12 to 24 V AC ±10% | |||||
Environment | Protective Enclosure | IP65 | ||||
Operating temperature range | During operation: 0 to 50°C, during storage: -25 to 85℃ (However, no freezing or condensation) | |||||
Withstand Voltage | 1,000 V AC for 1 min. between terminals and housing | |||||
Insulation Resistance | 50 MΩ or more (500 V DC measured via insulation resistance tester) between terminals and housing | |||||
Certification, standards, etc. | CE |
*1) For digital flow switch with the unit switching function (For the type without the unit switching function, fixed SI unit [L/min or L, m^3, m^3 × 10^3] will be set. )
*2) The flow rate display can be switched between the basic condition of 0°C and 101.3 kPa and the basic condition (ANR) of 20°C, 101.3 kPa and 65% RH.
*3) A straight section that is 8 times or more the pipe diameter should be provided to the pipe on the IN side of the product. If not, the accuracy may fluctuate by ±5% F.S. or more.
*4) It does not include lead.
*5) The accumulated flow rate value is reset when the power supply is turned off.
*6) Switch output and accumulated pulse output can be selected during the initial setting.
*7) Window comparator mode: Since the hysteresis (H) will reach 3 digits, separate P_1, P_2 or n_1, n_2 by 7 digits or more. (In the case of OUT2, n_1 and n_2 will become n_3 and n_4, and P_1 and P_2 will become P_3 and P_4.)
*8) All flow switches comply with CE marking.
*9) For wiring and thread standard, refer to the instruction manual.
*10) Even in striving to improve the quality, products may have small scratches, smears or variations in display color and brightness, etc., that do not affect the performance, verified as conforming products.
PF2A200-4C
PF2A200-A
PF2A200-A4C
PF2A200-B
PF2A200-B4C
PF2A200-M
PF2A200-M4C
PF2A200-MA
PF2A200-MA4C
PF2A200-MB
PF2A200-MB4C
PF2A201
PF2A201-4C
PF2A201-A
PF2A201-A4C
PF2A201-B
PF2A201-B4C
PF2A201-M
PF2A201-M4C
PF2A201-MA
PF2A201-MA4C
PF2A201-MB
PF2A201-MB4C
PF2A710-F02-27N
PF2A710-F02-27N-M
PF2A710-F02-67
PF2A710-F02-67-M
PF2A710-F02-67N
PF2A710-F02-67N-M
PF2A710-N01-27
PF2A710-N01-27-M
PF2A710-N01-27N
PF2A710-N01-27N-M
PF2A710-N01-67
PF2A710-N01-67N-M
PF2A710-N02-27
PF2A710-N02-27-M
PF2A710-N02-27N-M
PF2A710-N02-67
PF2A710-N02-67-M
PF2A710-N02-67N
PF2A710-N02-67N-M
PF2A711-03-27-M
PF2A711-03-27N
PF2A711-03-27N-M
PF2A711-03-67
PF2A711-03-67-M
PF2A711-03-67N
PF2A711-03-67N-M
PF2A711-F03-27
PF2A521-03
PF2A510-01
PF2A510-01-1
PF2A510-01-1-C
PF2A510-01-2
PF2A510-01-2-C
PF2A510-01-C
PF2A510-01N
PF2A510-01N-1
PF2A510-01N-2
PF2A510-02
PF2A510-02-1
PF2A310-A
PF2A310-A-M
PF2A300-A
PF2A300-A-M
PF2A301-A
PF2A301-A-M
PF2A311-A
PF2A311-A-M
PF2A751-04-27-M
PF2A750-02-27
PF2A750-02-27-M
PF2A721-03-27
PF2A721-03-27-M
PF2A721-03-67-M
PF2A711-03-27
PF2A710-02-67-M
PF2A710-01-27
PF2A710-01-27-M
PF2A710-01-27N
PF2A710-01-27N-M
PF2A710-01-67
PF2A710-01-67-M
PF2A710-01-67N
PF2A710-01-67N-M
PF2A710-02-27
PF2A710-02-27-M
PF2A710-02-27N