Compact Direct Operated 2/3 Port Solenoid Valve For Chemical Liquids LVM09/090 Series Specifications – Van điện từ khí nén SMC
Base Mounted Type (Without Sub-Plate) external appearance
Flow Rate Characteristics
- Water: Kv 0.015 / Cv 0.018
- Air: C 0.06 / b 0.2
*Kv, Cv values conform to JIS B 2005:1995. C and b values conform to JIB B8390:2000.
Model | Base Mounted Type | ||||
---|---|---|---|---|---|
LVM09R3 | LVM09R4 | LVM095R | |||
Valve Structure | Diaphragm type direct acting poppet (rocker type) | ||||
Valve Type | N.C. | N.O. | Universal | ||
Number of Ports | 2 | 3 | |||
Fluids*1 | Air, water, deionized water (pure water), diluent, detergent | ||||
Operating Pressure Range | -75 kPa to 0.2 MPa | ||||
Orifice Diameter | 1.1 mm | ||||
Response Time*8 | 10 ms or less (with pneumatic pressure) | ||||
Leakage Rate | Zero for both internal and external parts (with hydraulic pressure) | ||||
Proof Pressure*2 | 0.3 MPa | ||||
Ambient Operating Temperature*9 | 0 to 50°C | ||||
Operating Fluid Temperature*9 | 0 to 50°C (no freezing) | ||||
Volume of Valve Chamber*3 | 18 μL | ||||
Mounting Orientation*4 | Free | ||||
Enclosure | IP40 equivalent | ||||
Weight | 20 g | ||||
Rated Voltage | 12, 24 V DC | ||||
Allowable Voltage Fluctuation*5 | ±10% of rated voltage | ||||
Coil Insulation Type | Class B | ||||
Power Consumption (Current: at 24‑V Rated Voltage) |
Standard Type | 2 W (0.08 A) |
|||
With power-saving circuit | Inrush | 3.3 W (0.14 A) |
|||
Holding | 0.9 W | ||||
Coil Switching Noise*6 | 50 dB |
*1: Select an appropriate material for the wetted parts according to the type of fluid to be used. Be sure to check the chemical resistance beforehand.
*2: Indicates pressures which do not cause breakage or cracks after a 1 minute airtight test.
*3: Indicates the volume of the clearance inside the volume chamber after the volume of the diaphragm has been subtracted.
*4: As the body (orifice shape) is designed to eliminate residual liquid, mounting in a vertical orientation with the coil facing upward is recommended. If liquid pooling is not an issue, it may be installed in any orientation.
*5: If response speed is considered critical, take adequate regulations to prevent voltage fluctuations on the negative side.
*6: This value is depending on the measurement conditions and the sound level may change depending on the measurement conditions.
*7: See the SMC catalog if the valve is to be energized continuously for extended periods of time.
*8: According to JIS B8419:2010
{Value at an ambient and fluid temperature of 25°C, at rated voltage, at the maximum operating pressure (air) and when the N.C. (IN) port is pressurized}
The response time may vary depending on the supply pressure, fluid quality, piping conditions, ambient temperature, etc.
*9: Note that when the diaphragm material is Kalrez, the valve changeover time becomes significantly longer at ambient and fluid temperatures of 15°C or less in comparison to at room temperature (roughly 25°C).
LVM09R3-5A-3-Q
LVM09R3-5B-3-Q
LVM09R3-5B-6-Q
LVM09R3-5C-6
LVM09R3-5C-6-Q
LVM09R3-6A
LVM09R3-6A-3
LVM09R3-6A-3-Q
LVM09R3-6A-6
LVM09R3-6B-3
LVM09R3-6B-Q
LVM09R3-6C-Q
LVM09R3Y1-5A-6
LVM09R3Y1-5A-6-Q
LVM09R3Y1-5B-3-Q
LVM09R3Y1-5B-6
LVM09R3Y1-6A-3
LVM09R3Y1-6A-3-Q
LVM09R4-5A
LVM09R4-5A-Q
LVM09R4-5C
LVM09R4-5C-3
LVM09R4-5C-Q
LVM09R4-6A
LVM09R4-6A-6
LVM09R4-6B
LVM09R4-6B-3-Q
LVM09R4-6C
LVM09R4Y1-5A-6
LVM09R4Y1-5B-3
LVM09R4Y1-5B-3-Q
LVM09R4Y1-5B-6
LVM09R4Y1-5C-3-Q
LVM09R4Y1-6A-3
LVM09R4Y1-6A-6
LVM09R4Y1-6A-6-Q
LVM09R4Y1-6B-3
LVM09R4Y1-6B-3-Q
LVM09R4Y1-6C-3
LVM09R4Y1-6C-3-Q
LVM095R-5A
LVM095R-5A-3
LVM095R-5A-3-Q
LVM095R-5A-Q
LVM095R-5B-6
LVM095R-5B-Q
LVM095R-5C-3
LVM095R-5C-6
LVM095R-5C-6-Q
LVM095R-6A
LVM095R-6A-3
LVM095R-6A-3-Q
LVM095R-6A-6
LVM095R-6A-6-Q
LVM095R-6B
LVM095R-6B-Q
LVM095R-6C
LVM095R-6C-Q
LVM095RY1-5A-3
LVM095RY1-5A-6
LVM095RY1-5A-6-Q
LVM095RY1-5B-3-Q
LVM095RY1-5C-3
LVM095RY1-5C-3-Q