V114 (A) and V124 (A) JIS symbols
Fluid | Air |
---|---|
Ambient Temperature and Operating Fluid Temperature °C | -10 to +50 (no freezing) |
*1Response Time (for DC) ms | ON: 5 or less, OFF: 4 or less |
Maximum Operating Frequency Hz | 20 |
Manual Operation | Non-locking push type, locking type screwdriver operated type (slotted) |
Lubrication | Not required |
Mounting Position | Free |
*2: Impact Resistance / Vibration Resistance: m/s2 | 150/30 |
Enclosure | Dust-proof |
*1: Based on JIS B 8419:2010 dynamic performance test. (Standard type: coil temperature of 20°C, at rated voltage, with no surge voltage suppressor)
*2: Impact resistance: No malfunctions after testing using an impact tester under the following conditions: in the axial direction and at a right angle to the armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunctions occurred in a 1-sweep test between 45 and 2,000 Hz. The test was performed in both energized and non-energized states and in the axial direction and at a right angle to the armature. (Initial value)
Solenoid Specifications
Series | V114/V124 | V114A/V124A | ||
---|---|---|---|---|
Electrical Entry | Grommet (G) / (H), L-shaped plug connector (L), M-shaped plug connector (M) | |||
Coil rated voltage (V) | DC | 24, 12, 6, 5, 3 | ||
AC 50/60 Hz | 100, 110, 200, 220 | – | ||
Allowable Voltage Fluctuation | -10 to +10%* | |||
Power Consumption W | DC | Standard: 0.35 (with light: 0.4), with energy-saving circuit: 0.1 *[startup: 0.4, holding: 0.1] | 1 W (with light: 1.1) | |
Apparent Power VA | AC | 100 V | 0.78 (with light: 0.81) | – |
110 V [115 V] | 0.86 (with light: 0.89) [0.94 (with light: 0.97)] | – | ||
200 V | 1.18 (with light: 1.22) | – | ||
220 V [230 V] | 1.30 (with light: 1.34) [1.42 (with light: 1.46)] | – | ||
Surge Voltage Suppressor | See the SMC catalog. | |||
Indicator Light | LED |
- The 110‑V AC and 115‑V AC types are interchangeable. The 220‑V AC and 230‑V AC types are also interchangeable.
- For 115 V AC and 230 V AC, the allowable voltage fluctuation is -15 to +5% of the rated voltage.
- As the S, Z, and T types (with power saving circuit) have voltage drop due to the internal circuits, the allowable voltage fluctuation should be within the range given below.
S, Z type 24 V DC: -7% to +10%
12 V DC: -4% to +10%, T type 24 V DC: -8% to +10%
12 V DC: -6% to +10% - *If the valve is continuously energized for long periods, use an energy-saving type or DC specification.
*Refer to the SMC catalog for details.
Model
Valve Model Numbers | Switching Method | Type | Operating Pressure Range *4 (MPa) |
When Using in Vacuum (MPa) *4 | Piping connection port diameter | Weight (g) *2 | |||
---|---|---|---|---|---|---|---|---|---|
Port 1 | 3-Port | Port 1, Port 3 | 2 port | Grommet Type | L Type, M Type | ||||
V114 | N.C. | Standard | 0 to 0.7 | -100 kPa to 0.6 | -100 kPa to 0 | M5 × 0.8 | M5 × 0.8 | V1□4: 13 (27) V1□4A: 16 (30) |
Plug connector V1□4: 12 (26) V1□4A: 16 (29) |
V114A | N.C. | High flow rate | 0 to 0.7 | -100 kPa to 0.6 | -100 kPa to 0 | M5 × 0.8 | M5 × 0.8 | ||
V124*1 | N.C. | Standard | 0 to 0.7 | -100 kPa to 0 | -100 kPa to 0.6 | M5 × 0.8 | M5 × 0.8 | ||
V124A*1 | N.C. | High flow rate | 0 to 0.7 | -100 kPa to 0 | -100 kPa to 0.6 | M5 × 0.8 | M5 × 0.8 |
Valve Model Numbers | Flow Rate Characteristics | |||||
---|---|---|---|---|---|---|
1 → 2 [3 → 2 *3] | 2 → 3 [2 → 1 *3] | |||||
C [dm3/(s·bar)] | b | Cv | C [dm3/(s·bar)] | b | Cv | |
V114 | 0.037 | 0.11 | 0.008 | 0.054 | 0.35 | 0.015 |
V114A | 0.076 | 0.07 | 0.016 | 0.099 | 0.23 | 0.024 |
V124*1 | 0.054 | 0.35 | 0.015 | 0.037 | 0.11 | 0.008 |
V124A*1 | 0.099 | 0.23 | 0.024 | 0.076 | 0.07 | 0.016 |
*1: For V124 and V124A, apply pressure from port 3 and exhaust from port 1.
*2: Values in ( ) are with the subplate.
*3: For 10-V124 (A).
*4: When the difference between the primary and secondary sides is extremely small (guideline is 0.001 MPa or less), the quality of the air and lubricant oil in the solenoid valve (condensate mixture, etc.) may prevent air from being output or may cause the flow rate to dramatically decrease.
V114-1GZ-M5
V114-1M
V114-1M-M5
V114-1MOU
V114-1MOU-M5
V114-1MOZ
V114-2G-M5
V114-2MZ-M5
V114-5G
V114-5G-M5
V114-5GS
V114-5GZ
V114-5HU
V114-5HU-M5
V124-5G
V124-5G-M5
V124-5GR
V124-5GZ
V124-5HS-M5
V124-5HZ
V124-5LO-M5
V124-5LOU
V124-5M-M5
V124-5MU-M5
V124-5MZ-M5
V114-1G-M5
V114-1GB
V114-1GZ
V114-1GZ-M5
V114-1GZB-M5
V114-1H-M5
V114-1HZ
V114-1HZ-M5
V114-1L
V114-1L-M5
V114-1LN
V114-1LO
V114-1LOZ
V114-1LOZ-M5
V114-1LOZB
V114-1LZ
V114-1LZ-M5
V114-1LZB
V114-1LZB-M5
V114-4L-M5
V114A-5LB-M5
V114A-6LB
V114A-VG
V124-3LZ-M5
V124-5MP
V124-5MP-M5
V124-5MPZ
V124-5MPZ-M5
V124-SMZ-M5
V124A-6M
V124A-6M-M5
V124T-5LZB
V114-1LZB-M5
V114-1M
V114-1M-M5
V114-1MB
V114-1MOZ
V114-1MZ
V114-1MZ-M5
V114-1MZB-M5
V114-2G
V114-2G-M5
V124A-5MUB-M5
V124A-6MU-M5
V124A-RG-M5
V124T-5GZ-M5
V124T-5LOZ
V124T-5LOZB
V124T-5LZ
V124T-5MZ
V124T-5MZ-M5
V124T-6MZ-M5
V114-5LZB-M5
V114-5M
V114-5M-M5
V114-5MNZB
V114-5MOU
V114-5MOU-M5
V114-5MOZ-M5
V114-5MOZB
V114-5MS-M5
V114-5MU
V114-5MU-M5
V114-5MZ
V114-5MZ-M5