4/5-Port Solenoid Valve, Rubber Seal, SYJ3000 Series Specifications – Van Điện Từ SMC
SYJ3000 Series body ported type external appearance
SYJ3000 Series base mounted type external appearance
*1: Response Time ms (At 0.5 MPa) |
2 Position Single, Double | 15 or less |
---|---|---|
3 Position | 30 or less | |
Maximum Operating Frequency Hz | 2 Position Single, Double | 10 |
3 Position | 3 | |
Manual Operation | Non-locking push type, push-turn locking type screwdriver-operated type, push-turn locking manual-operation type | |
Pilot Exhaust Method | Pilot valve individual exhaust type, main valve / pilot valve common exhaust type | |
Lubrication | Not required | |
Mounting Orientation | Free | |
*2: Impact Resistance / Vibration Resistance: m/s2 | 150/30 | |
Enclosure | Dust-proof (*M8 connector is IP65) |
*Based on IEC60529.
*1: Based on JIS B8419:2010 dynamic performance testing. (Coil temperature of 20°C, at rated voltage, with no surge voltage suppressor)
*2: Impact resistance: No malfunction occurred. The test was performed once for each condition, in both energized and de-energized states, in the axial and right angle directions of the armature. (Initial value)
Vibration resistance: No malfunctions occurred in a 1-sweep test between 45 and 2,000 Hz. The test was performed in both energized and non-energized states and in the axial direction and at right angles to the main valve and armature. (Initial value)
Solenoid Specifications
Electrical Entry | Grommet (G)/(H), L plug connector (L), M plug connector (M), M8 connector (W) | ||
---|---|---|---|
Coil rated voltage (V) | DC | 24, 12, 6, 5, 3 | |
AC 50/60 Hz | 100, 110, 200, 220 | ||
Allowable Voltage Fluctuation | ±10% of rated voltage* | ||
Power Consumption W | DC | Standard | 0.35 (with light: 0.4) |
With power saving circuit | 0.1 (only with light) * [Startup 0.4, holding 0.1] |
||
*Apparent Power VA | AC | 100 V | 0.78 (with light: 0.81) |
110 V 115 V |
0.86 (with light: 0.89) [0.94 (with indicator light: 0.97)] |
||
200 V | 1.18 (with light: 1.22) | ||
220 V [230 V] |
1.30 (with light: 1.34) [1.42 (with light: 1.46)] |
||
Surge Voltage Suppressor | Diode (varistor for non-polar type) | ||
Indicator Light | LED |
- *The 110 V AC and 115 V AC types are interchangeable. The 220 V AC and 230 V AC types are also interchangeable.
- For 115 V AC and 230 V AC, the allowable voltage fluctuation is -15 to +5% of the rated voltage.
- For details, see the SMC catalog.
SYJ3120-1G-M3-F
SYJ3120-1GD-M3
SYJ3120-1GD-M3-F
SYJ3120-1GE-M3
SYJ3120-1GZ-M3
SYJ3120-1GZ-M3-F
SYJ3120-1GZD-M3
SYJ3120-1GZD-M3-F
SYJ3120-1GZE-M3-F
SYJ3120-1H-M3
SYJ3120-1H-M3-F
SYJ3120-1HZ-M3
SYJ3120-1HZ-M3-F
SYJ3120-1HZD-M3-F
SYJ3120-1L-M3
SYJ3120-1L-M3-F
SYJ3120-1LD-M3
SYJ3120-1LD-M3-F
SYJ3120-1LE-M3
SYJ3120-1LE-M3-F
SYJ3120-1LOZ-M3-F
SYJ3120-1LOZE-M3
SYJ3120-1LZ-M3
SYJ3120-1LZ-M3-F
SYJ3120-1LZD-M3
SYJ3120-1LZD-M3-F
SYJ3120-1LZE-M3
SYJ3120-1LZE-M3-F
SYJ3120-1M-M3
SYJ3120-1M-M3-F
SYJ3120-1MD-M3-F
SYJ3120-1ME-M3
SYJ3120-1ME-M3-F
SYJ3120-1MOZD-M3
SYJ3120-1MZ-M3
SYJ3120-1MZ-M3-F
SYJ3120-1MZD-M3
SYJ3120-1MZD-M3-F
SYJ3120-1MZE-M3
SYJ3120-1MZE-M3-F
SYJ3120-2G-M3
SYJ3120-2G-M3-F
SYJ3120-2GZE-M3
SYJ3130-1GE
SYJ3130-1GZ
SYJ3130-1GZE
SYJ3130-1H
SYJ3130-1HD
SYJ3130-1HZ
SYJ3130-1HZD
SYJ3130-1L
SYJ3130-1LE
SYJ3130-1LO
SYJ3130-1LOD
SYJ3130-1LOZ
SYJ3130-1LOZD
SYJ3130-1LOZE
SYJ3130-1LZ
SYJ3130-1LZD
SYJ3130-1LZE
SYJ3130-1M
SYJ3140-1G-M5
SYJ3140-1GE
SYJ3140-1GZ
SYJ3140-1GZ-M5
SYJ3140-1GZE
SYJ3140-1GZE-M5
SYJ3140-1H
SYJ3140-1H-M5
SYJ3140-1HD
SYJ3140-1HE
SYJ3140-1HE-M5
SYJ3140-1HZ-M5
SYJ3140-1HZD-M5
SYJ3140-1HZE-M5
SYJ3140-1L
SYJ3140-1L-M5
SYJ3140-1LD
SYJ3140-1LD-M5
SYJ3140-1LE
SYJ3140-1LE-M5
SYJ3140-1LN
SYJ3140-1LNZE