Download
3-Port Solenoid Valve VQ100 Series Specifications- Van Điện Từ SMC
3-Port Solenoid Valve VQ100 Series external appearance 1
3-Port Solenoid Valve VQ100 Series external appearance 2
3-Port Solenoid Valve VQ100 Series external appearance 3
Item | Type | |||||
---|---|---|---|---|---|---|
Standard Type (1 W) |
High-pressure type (1.5 W) |
Low-watt type (0.5 W) |
||||
Valve Construction | 3-Port Direct Operated Poppet type | |||||
Valve Specifications | Usable Fluids | Air | ||||
Maximum Operating Pressure | 0.7 MPa | 0.8 MPa | 0.7 MPa | |||
Minimum operating pressure (vacuum) | 0 MPa (-0.1 MPa*5) | |||||
Flow Rate Characteristics | 1→2 | C [dm3/(s·bar)] | 0.055 | 0.042 | ||
b | 0.22 | 0.27 | ||||
Cv | 0.014 | 0.011 | ||||
2→3 | C [dm3/(s·bar)] | 0.083 | 0.045 | |||
b | 0.28 | 0.28 | ||||
Cv | 0.021 | 0.012 | ||||
Response time*1 | ON: 3.5 ms, OFF: 2 ms | ON: 3.5 ms, OFF: 2.5 ms | ||||
Ambient Temperature and Operating Fluid Temperature | -10 to 50℃ *2 | |||||
Lubrication | Not required | |||||
Manual Operation | Non-locking push type / Locking type (tool required)*3 | |||||
Mounting Orientation | Free | |||||
Impact resistance / Vibration resistance*4 | 150/30 m/s2 | |||||
Enclosure | Dust-proof | |||||
Weight | 12.6 g (L/M plug connectors without sub-plate) | |||||
Electrical Specifications | Coil Rated Voltage | DC | 24 V, 12 V | |||
Allowable Voltage Fluctuation | ±10% of rated voltage | |||||
Coil Insulation Type | Class B or equivalent | |||||
Power Consumption (Current) | DC | 1 W (42 mA) | 1.5 W (63 mA) | 0.5 W (21 mA) | ||
Electrical Entry | Grommet Plug-in, L plug connector, M plug connector (With indicator light / surge voltage suppressor) |
*2: Based on JIS B 8374-1993. Value with indicator light / surge voltage suppressor (clean air). Variation accuracy ±1 ms
*2: Use dry air when operating at low temperatures and with no condensation.
*3: The locking type is a semi-standard specification.
*4: Impact resistance: No malfunction occurred when tested using a drop tester. The test was performed once for each condition, in both energized and de-energized states, in the axial and right angle directions of the armature. (Initial value)
Vibration resistance: No malfunctions occurred in a 1-sweep test between 45 and 2,000 Hz. The test was performed in both energized and non-energized states and in the axial direction and at a right angle to the armature. (Initial value)
*5: Select model numbers with a prefix of “10-” (Clean Series) when operating with a vacuum. Can be used with 3 (R) port vacuum, 1 (P) port vacuum burst pressure. (Differential pressure of 3 (R) and 1 (P) is up to the maximum operating pressure of each type.)
*6: The power saving type supports plug-in, L and M plug connectors for lead wire electrical entry.
Item | Type | ||||||
---|---|---|---|---|---|---|---|
Latching type | AC type | Large flow capacity type | Normally open type | ||||
Valve Specifications | Model number notation example | VQ110L-□ | VQ110-1□ VQ110-2□ |
VQ110U-□ | VQ120-□ | ||
Maximum Operating Pressure | 0.7 MPa | 0.6 MPa | 0.5 MPa | ||||
Minimum Operating Pressure | 0 MPa (-100 kPa*4, *5) | ||||||
Flow Rate Characteristics | 1→2*6 (3→2) |
C [dm3/(s·bar)] | 0.042 | 0.14 | 0.04 | ||
b | 0.27 | 0.26 | 0.11 | ||||
Cv | 0.011 | 0.036 | 0.009 | ||||
2→3注6) (2→1) |
C [dm3/(s·bar)] | 0.045 | 0.14 | 0.044 | |||
b | 0.28 | 0.25 | 0.3 | ||||
Cv | 0.012 | 0.036 | 0.011 | ||||
Response Time*2 | 5 ms or less | 15 ms or less | 5 ms or less | 5 ms or less | |||
Electrical Specifications | Power Consumption (Current) |
24 V DC | 1 W (42 mA)*7 | – | 0.35 W (15 mA)*3 | 1 W (42 mA) | |
12 V DC | 1 W (83 mA)*7 | – | 0.35 W (30 mA)*3 | 1 W (83 mA) | |||
100 V AC | 0.6 VA (6 mA) | 0.5 VA (5 mA) | – | ||||
110 V AC | 0.65 VA (5.9 mA) | 0.55 VA (5 mA) | – | ||||
200 V AC | 1.2 VA (6 mA) | 1.0 VA (5 mA) | – | ||||
220 V AC | 1.3 VA (5.9 mA) | 1.1 VA (5 mA) | – | ||||
Lead wire electrical entry*1 | Plug-in, L plug connector, M plug connector (With indicator light / surge voltage suppressor) |
*1: Grommet is available only for normally open type (without light/surge voltage suppressor). Normally open type is available only with 1 W DC specifications.
*2: Based on JIS B 8374-1993, with indicator light / surge voltage suppressor (clean air).
*3: Inrush 3.1 W (10 ms after energized), holding 0.35 W. +, – polarity present.
*4: Select model numbers with a prefix of “10-” (Clean Series) when operating with a vacuum. Can be used with 3 (R) port vacuum, 1 (P) port vacuum burst pressure. (Differential pressure of 3 (R) and 1 (P) is up to the maximum operating pressure of each type.)
*5: In the case of 1 (P) port vacuum and 3 (R) port vacuum release, use VQ120 (Normally open type)
. In this case, the prefix “10-” is not required.
*6: Value inside parentheses denote the air passage of the normally open type.
*7: +, – polarity present.
*8: Power-saving type: Inrush 1.5 W (10 ms after energized), holding 0.25 W. +, – polarity present.
VQ110-1FB
VQ110-1L
VQ110-1L-M3
VQ110-1L-M5
VQ110-1LB-M5
VQ110-1LO
VQ110-1LO-Q
VQ110-1M
VQ110-1M-M3
VQ110-1M-M5
VQ110-1MB-M3
VQ110-1MB-M5
VQ110-1MO
VQ110-1MO-M3
VQ110-1MO-M5
VQ110-1MO-Q
VQ110-2LB
VQ110-2MO
VQ110-3L-Q
VQ110-3LB
VQ110-5MOB
VQ110-6L-Q
VQ110-6LB
VQ110-6LOB
VQ110-6MB-M5
VQ110H-5M-M3
VQ110H-6G
VQ110L-1F
VQ110L-1F-Q
VQ110L-1L
VQ110L-1LO
VQ110L-1LO-Q
VQ110L-1M
VQ110L-1M-M5
VQ110L-1MO
VQ110L-1MO-Q
VQ110L-2L
VQ110L-2M
VQ110L-2MO
VQ110L-3L
VQ110L-3L-Q
VQ110L-3LO
VQ110L-3M
VQ110L-3M-Q
VQ120-5F-M5
VQ120-5F-Q
VQ120-5FB
VQ120-5FB-Q
VQ120-5G
VQ120-5G-M5
VQ120-5GB
VQ120-5L
VQ120-5L-M3
VQ120-5L-M5
VQ120-5L-M5-X42
VQ120-5L-Q
VQ120-5LB
VQ120-5LB-M5
VQ120-5LB-Q
VQ120-5LO
VQ120-5LO-M3
VQ120-5LO-Q
VQ120-5LOB
VQ120-5M
VQ120-5M-M3
VQ120-5M-M5
VQ120-5MB
VQ120-5MB-M5
VQ120-5MO
VQ120-5MO-M3
VQ120-5MO-M5
VQ120-5MO-Q
VQ120-5MOB
VQ120-6F-M5
VQ120-6L-M3