Speed Controller With Indicator Window Allowing Flow Rate To Be Controlled Numerically – Van tiết lưu SMC
The numerical indication of flow rate helps to reduce labor time and setting errors.
Speed Controller With Indicator, In-Line Type, AS-FS Series Specifications
Model | Applicable tubing outer diameter | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Metric size | Inch Size | |||||||||||
3.2 | 4 | 6 | 8 | 10 | 12 | 1/8 “ | 5/32 “ | 1/4 “ | 5/16 “ | 3/8 “ | 1/2 “ | |
AS1002FS□ | ● | ● | ● | – | – | – | ● | ● | ● | – | – | – |
AS2002FS□ | – | ● | ● | – | – | – | – | ● | ● | – | – | – |
AS2052FS□ | – | – | ● | ● | – | – | – | – | ● | ● | – | – |
AS3002FS□ | – | – | ● | ● | ● | ● | – | – | ● | ● | ● | – |
AS4002FS□ | – | – | – | – | ● | ● | – | – | – | – | ● | ● |
Model
Usable fluids | Air |
---|---|
Proof pressure | 1.5 MPa |
Max. operating pressure | 1 MPa |
Min. operating pressure | 0.1 MPa |
Ambient and fluid temperature | -5 to 60℃ (no freezing) |
Applicable tubing material | Nylon, soft nylon, polyurethaneNote), FEP, PFA |
Specifications
Note) Use caution at the max. operating pressure when using soft nylon or polyurethane tubing.
Model | AS1002FS□ | AS2002FS□ | AS2052FS□ | AS3002FS□ | AS4002FS□ | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Tube outer diameter | Metric size | ø3.2 | ø4 | ø6 | ø4 | ø6 | ø6 | ø8 | ø6 | ø8 | ø10 | ø12 | ø10 | ø12 |
Inch Size | ø1/8 “ | ø5/32 “ | ø1/4 “ | ø5/32 “ | ø1/4 “ | ø1/4 “ | ø5/16 “ | ø1/4 “ | ø5/16 “ | ø3/8 “ | – | ø3/8 “ | φ1/2 “ | |
C values: Sonic conductance dm3/(s·bar) |
Free flow | 0.3 | 0.4 | 0.6 | 0.4 | 0.6 | 1.0 | 1.2 | 1.1 | 1.6 | 2.2 | 2.6 | 2.4 | 3.5 |
Controlled flow | 0.3 | 0.4 | 0.6 | 1.0 | 1.2 | 1.3 | 1.9 | 2.7 | 3.3 | 2.8 | 4.1 | |||
b values: Critical pressure ratio | Free flow | 0.3 | 0.2 | 0.3 | 0.1 | 0.2 | 0.2 | 0.3 | 0.2 | |||||
Controlled flow | 0.2 | 0.3 | 0.4 | 0.2 | 0.2 | 0.3 | 0.1 | 0.2 | 0.1 | 0.2 |
Features of this product
Improved reproducibility of flow rate:Stable knob position when fully closed (zero flow rate) onto the contact face stopper (rotating stopper).
Minimal flow rate variation depending on the number of knob rotations.
Examples of mounting variations.
4 indicator window directions offer improved visibility.
Identification by index plate: It is possible to identify the product when multiple controllers are mounted and identify the flow direction by attaching an identification label.
AS-2AB
AS-3AB
AS-5AB
AS-6AB
AS-7AB
AS-8AB
AS-9AB
AS-11AB
AS-12AB
AS-13AB
AS-14AB
AS-15AB
AS-16AB
AS-17AB
AS-19AB
AS-20AB
AS-21AB
AS-22AB
AS-23AB
AS-24AB
AS-25AB
10-AS1002FS1-06
10-AS1002FS-04
10-AS1002FS-06
10-AS2002FS1-06
10-AS2002FS2-06
10-AS2002FS-04
10-AS2002FS-06
10-AS2052FS1-08
10-AS2052FS-07
10-AS2052FS-08
10-AS3002FS-11
AS-10AB
AS-4AB
AS1002FS1-01
AS1002FS1-03
AS1002FS1-04
SALE
AS1002FS1-06
AS1002FS1-07
AS1002FS1-23
AS1002FS2-01
AS1002FS2-03
AS1002FS2-04
AS1002FS2-06
AS1002FS2-07
AS1002FS2-23
AS2002FS1-04
AS2002FS1-06
AS2002FS1-07
AS2002FS2-03
AS2002FS2-04
AS2002FS2-06
AS2002FS2-07
AS2002FS3-03
AS2052FS1-06
AS2052FS1-07
AS2052FS1-08
AS2052FS1-09
AS2052FS2-06
AS2052FS2-07
AS2052FS2-08
AS3002FS1-06
AS3002FS1-07
AS3002FS1-08
AS3002FS1-09
AS3002FS1-10
AS3002FS1-11
AS3002FS1-12
AS3002FS2-06
AS4002FS1-11
AS4002FS1-12
AS4002FS1-13
AS4002FS2-10
AS4002FS2-11
AS4002FS2-12
AS4002FS2-13
AS4002FS3-10
AS4002FS3-11
AS4002FS3-12
AS1002FS1-04-X21
AS1002FS1-04-X214
AS1002FS1-06-X21
AS1002FS1-06-X214
AS1002FS2-06-X21
AS1002FS2-06-X214
AS1002FS3-06-X214
AS1002FS-04-X21
AS1002FS-04-X214
AS1002FS-06-X12
AS1002FS-06-X214
AS2002FS1-06-X21
AS2002FS2-06-X21
AS2002FS3-06-X21