Download
Cảm Biến Áp Suất SMC IFW5 Series IFW510 IFW520 IFW550
Specifications of Diaphragm-Type Flow Switch IFW5 Series – Cảm Biến Áp Suất SMC
[Features] · Low flow (1 L/min) setting is possible· Easy to set
It can be set with a screwdriver from the outside without removing the cover
· With light [Applications] · Used for detection and confirmation of flow as a general-purpose water cutoff, water reduction relay in cooling water fixtures in general industrial machinery.

External appearance of IFW5 Series
Fluid | Water / Non corrosive liquid* | |
---|---|---|
Operating Pressure | 0.1 to 0.6 MPa | |
Water resistance | 1.2 MPa | |
Operating temperature range | -5 to 60°C (no freezing) | |
Action | Diaphragm Regulator | |
Insulation Resistance | 100 MΩ or more (500 DC by insulation resistance tester) | |
Withstand Voltage | 1,500 V AC for 1 minute | |
Contact | Without terminal box: 1ab | |
With terminal box: 1a and 1b | ||
Connection port size | 3/8, 1/2, 3/4 | |
Liquid-contacting parts material | Body | CAC408 |
Rod | C3604B | |
Diaphragm | *)NBR |
* Please contact the manufacturer support center for further details of use.
*) Select “-X404” for ozone environment.
Model
Model | Set flow rate range L/min | Maximum flow rate L/min | *) Hysteresis L/min |
---|---|---|---|
IFW510 | 1 to 10 | 20 | 1 or less |
IFW520 | 10 to 20 | 25 | 1.5 or less |
IFW550 | 20 to 50 | 60 | 3 or less |
*) Hysteresis is the flow rate required to move the micro switch from the operating position (ON signal) to the return position (OFF signal). (Typical value)
Microswitch rating
Voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Load resistance | Lamp load | Inductive load | Electric motor load | |||||
N.C. | N.O. | N.C. | N.O. | N.C. | N.O. | N.C. | N.O. | |
AC125V | 5 | 5 | 1.5 | 0.7 | 4 | 4 | 2.5 | 1.3 |
AC250V | 5 | 5 | 1 | 0.5 | 4 | 4 | 1.5 | 0.8 |
DC8V | 7 | 5 | 3 | 3 | 5 | 4 | 3 | 3 |
DC14V | 5 | 5 | 3 | 3 | 4 | 4 | 3 | 3 |
DC30V | 5 | 5 | 3 | 3 | 4 | 4 | 3 | 3 |
DC125V | 0.4 | 0.4 | 0.1 | 0.1 | 0.4 | 0.4 | 0.1 | 0.1 |
DC250V | 0.3 | 0.3 | 0.05 | 0.05 | 0.3 | 0.3 | 0.05 | 0.05 |
Structure and operating principle diagram

IFW5 Series structure and operating principle diagram
Operating Principle
When water flows, a differential pressure is generated before and after the orifice at the port of body 1. This differential pressure is detected by a pair of upper and lower diaphragms, rod 2 is displaced downward, operating lever 4 is lowered, and the micro switch is turned on.
If the flow rate is increased, the rod will be displaced downwards by 2, and if it is decreased, it will be displaced upwards. In addition, the adjustment gear 5 can be rotated and the gear 3 can be moved vertically to detect signals at any flow rate.
IFW510-03-00-Q
IFW510-03-01
IFW510-03-01-Q
IFW510-03-02
IFW510-03-03
IFW510-03-04
IFW510-03-10
IFW510-03-10-Q
IFW510-03-11
IFW510-03-11-Q
IFW510-03-12
IFW510-03-13
IFW510-03-13-Q
IFW510-03-14
IFW510-03-20
IFW510-03-20-Q
IFW510-03-21
IFW510-03-22
IFW510-03-23
IFW510-03-24
IFW510-03-55
IFW510-03-55-Q
IFW510-03-56
IFW510-03-56-Q
IFW510-03-65
IFW510-03-65-Q
IFW510-03-76
IFW510-03-76-Q
IFW510-03-85
IFW510-03-85-Q
IFW510-03-86
IFW510-03-86-Q
IFW510-04-00
IFW510-04-00-Q
IFW510-04-01
IFW510-04-01-Q
IFW510-04-02
IFW510-04-03
IFW510-04-04
IFW510-04-04-Q
IFW510-04-10
IFW510-04-10-Q
IFW510-04-11
IFW510-04-11-Q
IFW510-04-12
IFW510-04-12-Q
IFW510-04-13
IFW510-04-13-Q
IFW510-04-14
IFW510-04-20
IFW510-04-20-Q
IFW510-04-21
IFW510-04-22
IFW510-04-23
IFW510-04-24
IFW520-03-01
IFW520-03-02
IFW520-03-03
IFW520-03-04
IFW520-03-10
IFW520-03-10-Q
IFW520-03-11
IFW520-03-11-Q
IFW520-03-12
IFW520-03-13
IFW520-03-14
IFW520-03-20
IFW520-03-20-Q
IFW520-03-21
IFW520-03-22
IFW520-03-55
IFW520-03-56
IFW520-03-65
IFW520-03-66
IFW520-03-75
IFW520-03-76
IFW520-03-85
IFW520-03-86
IFW520-04-00
IFW520-04-00-Q
IFW520-04-01
IFW520-04-01-Q
IFW520-04-02
IFW520-04-03
IFW550-03-01
IFW550-03-02
IFW550-03-03
IFW550-03-10
IFW550-03-11
IFW550-03-12
IFW550-03-13
IFW550-03-14
IFW550-03-21
IFW550-03-22
IFW550-03-55
IFW550-03-56
IFW550-03-65
IFW550-03-66
IFW550-03-75
IFW550-03-76
IFW550-03-85
IFW550-03-86
IFW550-04-00
IFW550-04-00-Q
IFW550-04-01
IFW550-04-02
IFW550-04-03
IFW550-04-04
IFW550-04-10
Giới thiệu SMC Việt Nam
SMC là thương hiệu hàng đầu thế giới trong lĩnh vực công nghệ khí nén, cung cấp các giải pháp tiên tiến nhằm hỗ trợ tự động hóa và tối ưu hóa quy trình sản xuất.
Với nền tảng vững chắc trong ngành, SMC Việt Nam luôn đi đầu trong việc nghiên cứu, đổi mới và phát triển sản phẩm, góp phần nâng cao năng suất và tiết kiệm lao động cho các doanh nghiệp công nghiệp.
Với phương châm “đóng góp vào tự động hóa và tiết kiệm lao động trong ngành công nghiệp”, SMC Việt Nam không ngừng cải tiến và mang đến những sản phẩm công nghệ tiên tiến nhất.
SMC Việt Nam cam kết cung cấp những giải pháp hiện đại, giúp khách hàng duy trì lợi thế cạnh tranh trên thị trường.
Medin Company cung cấp các sản phẩm SMC tại Việt Nam.
Đa dạng các sản phẩm và giải pháp khí nén phục vụ cho nhiều ngành công nghiệp khác nhau, bao gồm:
- Xy lanh khí nén – Giúp kiểm soát chuyển động chính xác và hiệu quả.
- Van điện từ – Ứng dụng rộng rãi trong điều khiển luồng khí nén.
- Bộ lọc khí nén – Đảm bảo chất lượng khí nén tối ưu.
- Cảm biến và bộ điều khiển – Tăng cường tự động hóa trong quy trình sản xuất.
———————-
👉 Xem thêm sản phẩm của SMC
Liên Hệ Medin Co., Ltd
- Công ty TNHH Mễ Đình được thành lập từ năm 2006.
- Từ đó đến nay Medin luôn là Công ty dẫn đầu về lĩnh vực Tự Động Hoá ở thị trường trong và ngoài nước với hơn 1,000 khách hàng, cùng với rất nhiều dự án lớn nhỏ cho các nhà máy sản xuất.
- Chúng tôi cung cấp cho khách hàng những giải phát tuyệt vời nhất trong việc ứng dụng Tự Động Hoá vào sản xuất
- Phương châm: “Giải pháp của chúng tôi, lợi ích của khách hàng”
- Giá trị cốt lõi: “Uy tín là sự tồn tại của chúng tôi”
- Hơn 20 năm kinh nghiệm, chúng tôi có đội ngũ kỹ sư nhiều kinh nghiệm, có khả năng tư vấn, đưa ra giải pháp có lợi nhất cho khách hàng.
- Sự tin tưởng và đồng hành của khách hàng là động lực để Medin phát triển cao hơn và xa hơn.