Clean Air Module Common Specifications
Model | LLB3 | LLB4 | ||
---|---|---|---|---|
Applicable Fluid | Clean Air, N2gas (Inlet air conditions equivalent to ISO 8573-1 and quality class 1.4.1 to 1.6.1)*3 | |||
Maximum Operating Pressure | 0.7 MPa | |||
Set Pressure | 0.05 to 0.4 MPa | |||
Withstand Pressure | 1.0 MPa | |||
Working Fluid Temperature | 5℃ to 45°C (no freezing) *Guaranteed range of digital flow switch: 15 to 35°C. |
|||
Ambient Temperature | ||||
Flow Rate Range*1 | 5 to 100 L/min (ANR) | 50 to 500 L/min (ANR) | ||
Filtration*2 | 0.01 μm (filtration efficiency 99.99%) | |||
Fluid Contact Space | – | Grease-free, silicone-free | ||
Material | Body | PBT | ||
Module Connection Packing | FKM | |||
Single-Action Fitting Packing | EPDM |
*1: The maximum flow rate varies depending on set pressure. Refer to “Flow Rate Characteristics” graph for details.
*2: Measured under manufacturer’s specified conditions.
*3: Refer to Operating Environment (catalog p. 344).
Digital Flow Switch Unit Specifications
Model | LLB3 | LLB4 | ||
---|---|---|---|---|
Detection Type | Heat type | |||
Measured Flow Rate Range | 5 to 100 L/min | 50 to 500 L/min | ||
Minimum Unit Setting | 1 L/min | 5 L/min | ||
Accumulated Pulse Flow Rate Exchange Value (Pulse Width: 50 [ms]) | 1 L/pulse | 5 L/pulse | ||
Accumulated Flow Rate Range | 0 to 999,999 L | |||
Linearity | ±5% F.S. or less (15 to 35°C, 25°C reference) | |||
Repeatability | ±2% F.S. or less | |||
Temperature Characteristics | ±5% F.S. or less (15 to 35°C, 25°C reference) | |||
Specifications | Switch Output | – | NPN or PNP open collector output | |
Maximum Load Current | 80 mA | |||
Maximum Applied Voltage | 30 V DC (at NPN output) | |||
Internal Voltage Drop | NPN output: 1 V or less (at 80 mA) PNP output: 1.5 V or less (at 80 mA) | |||
Analog Output | Voltage Output | Output voltage 1 to 5 V | ||
Allowable load resistance 100 kΩ or more | ||||
Current Output | Output current 4 to 20 mA | |||
Allowable load resistance 300Ω or less (12 V DC), 600Ω or less (24 V DC) | ||||
Status LEDs | When turned ON, OUT1: Green, OUT2: Red (where output is analog, OUT1 only) | |||
Response Time | 1S or less | |||
Power Supply Voltage | 12 to 24 V DC (Ripple ±10% or less) | |||
Current Consumption | 160 mA or less | 170 mA or less | ||
Withstand Voltage | 1,000 V AC, for 1 minute between external terminal and case | |||
Insulation Resistance | 50 MΩ or more (500 V DC measured with megohmmeter) between external terminal and case | |||
Noise Resistance | 1,000 V p-p, pulse width 1 μs, rise time 1 ns | |||
Lead Wire | Lead wire with connector | |||
Enclosure | IP65 | |||
Fluid Contact Space Material | Mesh | SUS | ||
Sensor Housing | PBT | |||
Sensor | Lead glass (RoHS-exempt material) | |||
Ptlr | ||||
FeNl |
ON/OFF Valve Unit Specifications
Model | LLB3 | LLB4 | |
---|---|---|---|
Pilot Pressure (ON/OFF Valve Operating Pressure) | 0.4 to 0.5 MPa | ||
Back Pressure | 0.4 MPa or less | ||
Valve Type | N.C. | ||
Orifice Diameter | 4 mm | 8 mm | |
Cv Factor | 0.35 | 1.7 | |
Fluid Contact Space Material | Diaphragm | PTFE | |
Valve Leakage | 1 cm3/min (ANR) or less |
Filter Unit Specifications
Model | LLB3 | LLB4 | |
---|---|---|---|
Filtration*1 | 0.01 μm (filtration efficiency 99.99%) | ||
Element Proof Differential Pressure*2 | 0.5 MPa | ||
Processing Flow Rate | Up to 100 L/min (ANR) | Up to 500 L/min (ANR) | |
Fluid Contact Space Material | Filter Case | PC | |
Hollow Fiber | PP | ||
Potting | PU |
*1: Measured under manufacturer’s specified conditions.
*2: This means that the element will not break at 0.5 MPa. Refer to installation precautions prior to use.
Pressure Reducing Valve Unit Specifications
- Relief mechanism: LLB3, LLB4 / Non-relief
- Fluid contact space material (Diaphragm): LLB3, LLB4 / FKM
Throttle Valve Unit Specifications
- Cv factor: LLB3 / 0.28, LLB4 / 1.4
- Number of needle rotations: LLB3 / 8 rotations, LLB4 / 10 rotations
- Fluid contact space material (needle): LLB3, LLB4 / SUS
Product Outline Dimensional Drawing
(Unit: mm)
LLB3-1-P□R□V□SF dimensional drawing
*Cannot be used. If a pressure gauge, etc. is screwed in, there is risk of damage.
(Unit: mm)
LLB4-1-P□R□V□SF dimensional drawing
*Cannot be used. If a pressure gauge, etc. is screwed in, there is risk of damage.
Component Parts
LLB Series component parts
No. | Description | Note | |
---|---|---|---|
1 | Clean regulator ass’y | – | – |
2 | Pressure outlet port ass’y | – | – |
3 | ON/OFF valve ass’y / Air operated valve | Without flow adjuster | – |
With flow adjuster | – | ||
ON/OFF valve ass’y / Manual operation valve | – | – | |
4 | Throttle valve ass’y | – | – |
5 | Digital flow switch ass’y | 5 to 100 L/min | With L-type connector With lead wire (3 m) |
50 to 500 L/min | |||
6 | Clean air filter ass’y | øWith 10-mm diameter fitting | With single-action fitting |
Rc 1/4 | Threaded type | ||
NPT 1/4 | |||
øWith 10-mm diameter pipe fitting, with differential pressure gauge | With single-action fitting | ||
Rc 1/4, with differential pressure gauge | Threaded type | ||
NPT 1/4, with differential pressure gauge | |||
Replacement element | – | ||
7 | End plate ass’y | øWith 10-mm diameter fitting | With single-action fitting |
Rc 1/4 | Threaded type | ||
NPT 1/4 | |||
øWith 12-mm diameter fitting | With single-action fitting | ||
Rc 3/8 | Threaded type | ||
NPT 3/8 |
*Each module comes with 2 connection fittings.
Product Flow Rate Characteristics
Standard type (100 L/min)
LLB3-1-P1R1VSF flow rate characteristics graph (number of needle rotations)
LLB3-1-P1R1VSF flow rate characteristics graph (fluid pressure)
High Flow Type (500 L/min)
LLB4-1-P1R1VSF flow rate characteristics graph (number of needle rotations)
LLB4-1-P1R1VSF flow rate characteristics graph (fluid pressure)
Test Conditions
Product models: LLB3-1-P1R1VSF and LLB4-1-P1R1VSF
Supplied pressure: 0.5 MPa
Pressure setting conditions and measured position: Pressure is set by turning the regulator knob with ON/OFF valve turned off.
Pressure is measured at the pressure outlet port.
Installation diagram based on test conditions
Precautions
- *Ensure that you read the specific product precautions prior to use.
- *See the manufacturer’s catalog for product information other than the above.
- *Product pictures are example representations for the product series. Please be aware that actual product specifications may be different.
Design and Selection
- *Confirm the specifications: Give due consideration to the operating conditions such as the application, fluid and environment, and use within the operating ranges specified in the manufacturer’s catalog.
- *Ensure sufficient maintenance space: Provide the required space for maintenance inspection.
- *Fluid pressure range: Supplied fluid pressure must be within the operating pressure range specified in the manufacturer’s catalog.
Mounting
- *If air leakage increases, or equipment does not operate correctly, stop use immediately.
- *After mounting, perform suitable function and leak testing to confirm that the mounting is correct.
Basic Information
Compressed Air Quality | General Dry Air |
---|
LLB3-1-P1F
LLB3-1-P1F1
LLB3-1-P1R1F
LLB3-1-P1R1F1
LLB3-1-P1R1SF
LLB3-1-P1R1V1F
LLB3-1-P1R1V1SF
LLB3-1-P1R1V1SF1
LLB3-2-F
LLB3-2-F1
LLB3-2-P1R1F
LLB3-2-P1R1SF
LLB3-2-P1R1V1F
LLB3-2-P1R1V1F1
LLB3-2-P1R1V1SF
LLB3-2N-P1R1V1SF1
LLB3-2N-P1RVF
LLB3-2N-P3R1VSF
LLB3-2N-P6VSF
LLB3-2N-R1SF1
LLB3-2N-R1VSF
LLB4-1-P1F
LLB4-1-P1R1F
LLB4-1-P1R1SF
LLB4-1-P1R1V1F
LLB4-1-P1R1V1SF
LLB4-1-P1R1V2F
LLB4-1-P1R1V2SF
LLB4-3-F
LLB4-3-P1F
LLB4-3-P1R1F
LLB4-3-P1R1SF
LLB4-3-P1R1V1F
LLB4-3-P1R1V1SF
LLB4-3-P1R1V2F
LLB4-3-P1R1V2SF
LLB4-3N-P1RVF
LLB4-3N-P1RVSF
LLB4-3N-R1F
LVB2-3-1
LVB2-3-2
LVB2-4
LVB3-1
LVB3-2
LVB3-6-1
LVB3-6-2
LVB3-6-3
LVB3-6-4
LVB3-6-5
LVB3-6-6
LVB3-7-2
LVB3-7-2-1
LVB3-7-3
LVB3-7-3-1
LVB4-1
LVB4-2
LVB4-3
LVB4-3-1
LVB4-3-2
LVB4-4
LVB4-6-1